BX-350 Infrared Fast Calibrator
- Descrizione
- Inchiesta
Descrizione
Calibrator
BX-350 parameters:
[introduzione]
BX-350 Portable Infrared Calibrator (Blackbody Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has 2 types of power supply to choose from, one is AC220V and the other is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged
[feature]
Small and compact design, can calibrate infrared temperature to 350 ℃, large 2.25 pollici (57mm) black body
Precisione: Ambient operating temperature is 5-35 °C (41-95 ° f), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.5 °C; 50 °C <temperature≤100 ° C (± 1.2℉; 122℉<temperature≤212℉)
± 1.0 ℃; 100 ℃ < temperature≤200 ℃ (± 2.0 ℉; 212 ℉ < temperature≤392 ℉)
± 1.5 ℃; 200 ℃ < temperature≤350 ℃ (± 3.0 ℉; 392 ℉ < temperature≤662 ℉)
Stabilità: Ambient operating temperature is 5-35 ℃ (41-95 ° f), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.1 ℃; 50 ℃ <temperature≤100 ℃ (± 0.2 ℉; 122 ℉ <temperature≤212 ℉)
± 0.2 ℃; 100 ℃ < temperature≤200 ℃ (± 0.4 ℉; 212 ℉ < temperature≤392 ℉)
± 0.3 ℃; 200 ℃ < temperature≤350 ℃ (± 0.6 ℉; 392 ℉ < temperature≤662 ℉)
[Technical Index]
Allineare: 50 ° C-350 ° C (122 ° F-662 ° F)
Target emissivity: fixed at 0.95
Risoluzione: 0.1 ℃ / 0.1 ℉
Heating time: 30 minutes to the maximum temperature
Tempo di raffreddamento: 40 minutes to 100 °C (122 ° f)
Target diameter: 57mm
Alimentazione elettrica: 220V.AC (± 10%), 1.25UN / 110V.AC (± 10%), 2.5
Dimensioni: 180 × 114 × 233mm
Peso: 3kg
Calibrator
X-500 parameters:
[introduzione]
BX-500 Portable Infrared Calibrator (Black Body Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has two kinds of power supply to choose from, one is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged.
[feature]
1. Small and compact design,
2. Calibrate infrared high temperature to 550 ℃,
3. Hit a 2.25 pollice (57mm) black body target.
Precisione
Ambient operating temperature: 5-35 °C (41 ~ 95 ° f), umidità relativa: 15 ~ 80%, air pressure: 75kPa ~ 106kPa
± 0.8 ℃; 50 ℃ <temperature≤100 ℃ (± 1.6 ℉; 122 ℉ <temperature≤212 ℉)
± 1.6 °C; 100 °C <temperature≤200 ° C (± 3.2 ° f; 212 ° f <temperature≤392 ° F)
± 2.8 °C; 200 °C <temperature≤500 ° C (± 5.6 ° f; 392 ° f <temperature≤932 ° F)
stability
The ambient operating temperature is between 5 E 35 °C (41 A 95 ° f), the relative humidity is 15 A 80%, and the air pressure is 75 kPa to 106 KPA
± 0.1 °C; 50 °C <temperature≤100 ° C (± 0.2 ° f; 122 ° f <temperature≤212 ° F)
± 0.2 °C; 100 °C <temperature≤200 ° C (± 0.4 ° f; 212 ° f <temperature≤392 ° F)
± 0.4 °C; 200 °C <temperature≤500 ° C (± 0.8 ° f; 392 ° f <temperature≤932 ° F)
[Technical Index]
Allineare: 50 ° C-500 ° C (122 ° F-932 ° F)
Target emissivity: fixed at 0.95
Risoluzione: 0.1 ℃ / 0.1 ℉
Heating time: 40 to maximum temperature
Tempo di raffreddamento: 45 minutes to 100 °C (122 ° f)
Target diameter: 57mm
Alimentazione elettrica: 220V.AC (± 10%), 1.25UN / 110V.AC (± 10%), 2.5
Dimensioni: 180 × 114 × 233mm
Peso: 3kg
|
BX-350 |
BX-500 |
|
|
Calibration temperature range |
50-350℃ |
50-500℃ |
|
Precisione di base |
±0,5℃(100℃) |
±0,5℃(100℃) |
| ±1.2℃(350℃) | ±1.8℃(500℃) | |
|
Stability rate |
±0,1℃(100℃) | ±0,1℃(100℃) |
| ±0.2℃(350℃) | ±0.3℃(500℃) | |
| heating time | 30 minutes to maximum temperature | 40 minutes to maximum temperature |
| Tempo di raffreddamento | 30 minutes to 100 ℃ | 45 minutes to 100 ℃ |
| Risoluzione | 0.1℃ | |
| Target diameter | 57mm (2.25 pollici) | |
| Target emissivity | Fixed 0.95 | |
| power supply |
AC 230v (± 10) 1.5UN; or AC 110v3A |
|
| misurare | 181 * 114 * 233mm | |
| peso | 2682G | |

























