ISO 13320: Global Technical Guidelines for Laser Diffraction Particle Size Analysis

ISO 13320: Global Technical Guidelines for Laser Diffraction Particle Size Analysis

1. Standard Overview: The “Universal Language” for Laser Diffraction Particle Size Analysis
ISO 13320, officially titled “Particle size analysis — Laser diffraction methods”, is a core technical standard developed by the International Organization for Standardization (ISO) for the measurement of particle size distribution. First released in a divided part format in 1999 (ISO 13320-1:1999) and undergoing its first integrated revision in 2009, the currently valid version is ISO 13320:2020. This version incorporates the latest technological advancements in areas such as instrument qualification assessment and measurement accuracy evaluation.
As a globally unified guideline for laser diffraction particle size analysis, its core value lies in providing a standardized method for particle size measurement of various two-phase systems, including powders, sprays, aerosols, suspensions, emulsions, and bubbles in liquids. It addresses the issue of comparability of measurement results between different instruments and laboratories. Currently, many countries around the world have adopted it as their national standards, such as Germany (DIN ISO 13320), the United Kingdom (BS ISO 13320), and South Korea (KS A ISO 13320). China also plans to release GB/T 19077-202X to replace the previous version through equivalent adoption.

2. Technical Principle: The Correlation Logic Between Light Scattering and Particle Size
The measurement principle of the laser diffraction method is based on the law of interaction between light and particles: when a laser beam passes through a group of particles, the particles cause diffraction and scattering phenomena. There is a definite mathematical relationship between the intensity distribution of the scattered light and the particle size — small particles produce wide-angle scattering, while large particles mainly scatter within a small angle range. By capturing the angular distribution data of the scattered light intensity with a detector and calculating it in combination with an optical model, the particle size distribution can be inferred.
The standard specifies the application scenarios of two core optical models:
a. Fraunhofer Theory: Applicable only to opaque particles with a particle size much larger than the light wavelength (d≫λ). It does not require input of particle refractive index parameters, is simple to calculate, and is suitable for rapid measurement of particles larger than 50μm.
b. Mie Theory: It is an accurate solution for light scattering and requires input of the complex refractive index (N=n-ik, where n is the real part of refraction and k is the imaginary part of absorption) of the particles and the dispersion medium. It is applicable for full-range measurement from 0.1μm to 3mm, and its analysis accuracy for fine particles below 2μm is significantly better than that of the Fraunhofer Theory.
It is worth noting that the optical model of the standard defaults to spherical particles. Therefore, for non-spherical particles, the measured “equivalent spherical diameter” may differ from the results obtained by other methods such as sieving and sedimentation — this characteristic must be taken into account when comparing results.

3. Core Content: From Application Scope to Implementation Specifications
(1) Application Boundaries and Expansion Capabilities
The basic applicable particle size range of ISO 13320:2020 is 0.1μm to 3mm, covering a wide range from submicron colloids to millimeter-sized particles. With special instruments (such as wide-angle detectors and high-power laser sources) and optimized test conditions (such as customized dispersion systems), the measurement range can be extended to both ends: breaking through the upper limit of 3mm to the field of coarse particles, or going below 0.1μm to enter the field of nanoparticle measurement.
This standard is applicable to particle measurement of almost all two-phase systems, but it explicitly excludes “specific requirements for special materials” — for example, special scenarios such as sterile particles in the pharmaceutical field and radioactive particles in the nuclear industry require supplementary implementation in conjunction with industry-specific standards.
(2) Key Technical Requirements
•Instrument Qualification Assessment: This is the core content added in the 2020 version. It requires users to conduct systematic qualification of instruments, including calibration verification (using certified reference materials CRM), performance verification (such as intermediate precision testing), and applicability evaluation, to ensure the reliability of the instrument within the entire measurement range.
•Measurement Parameter Control:
a.Complex Refractive Index: The refractive index of the dispersion medium (such as water and air) can be queried through a database, while the refractive index of the sample needs to be accurately measured or estimated based on experience (for example, k=0 for transparent particles and k=1 for black particles). Parameter deviations may lead to measurement errors of more than 10%.
b.Shading rate : It needs to be controlled within the range recommended by the instrument (usually 3%-15%) to avoid result distortion caused by multiple scattering.
•Result Expression Specifications: Referring to the requirements of the ISO 9276 series standards, it is necessary to provide both graphical representation (such as a particle size distribution curve) and characteristic parameters (such as D10, D50, D90 percentile diameters), and specify the sources of measurement uncertainty.
(3) Core Changes in Version Evolution
Compared with the 2009 version, the key upgrades of ISO 13320:2020 include:
•Strengthening technical guidance for fine particle measurement to reflect the latest progress in instrument design.
•Adding a user-led instrument accuracy assessment and qualification determination process.
•Refining the result interpretation and limitation description for non-spherical particle measurement.

4. Application Scenarios: The Cornerstone of Cross-Industry Particle Size Control
The efficiency and versatility of the laser diffraction method make ISO 13320 an essential technical standard in various industries. Typical applications include:
(1) Industrial Manufacturing Field
•Powder Metallurgy: By monitoring the particle size distribution (such as D50 value) of metal powders, the density uniformity of sintered parts is ensured.
•Coatings and Inks: Controlling the particle size of pigments (usually 20-100μm) to ensure the hiding power and leveling property of the coating.
•Pharmaceutical Industry: The particle size of active pharmaceutical ingredients in oral solid preparations directly affects the dissolution rate and needs to strictly comply with the measurement specifications of ISO 13320.
(2) Energy and Environmental Field
•New Energy Materials: The particle size distribution (1-20μm) of lithium battery cathode materials (such as ternary materials) affects the battery capacity and cycle life.
•Atmospheric Monitoring: The measurement of aerosol particles (0.1-10μm) provides data support for PM2.5 source tracing.
(3) Food and Agricultural Field
•Dairy Processing: The particle size of fat globules in emulsions (0.1-5μm) determines the taste and shelf life of milk.
•Pesticide Formulations: The size distribution of spray particles directly affects the utilization rate of pesticide efficacy and needs to be accurately controlled through standard methods.

Our product GA-2607 Dry and Wet Integrated Laser Particle Size Analyzer meets ISO13320.

GA-2607 dopts the most advanced Mie scattering principle and convergent Fourier transform optical path. High-density probe and full range seamless test method ensure the accuracy and repeatability of test results. The unique wet circulation dispersing system ensures the particle to ensure that there is no particle deposition in the test process and no waste liquid accumulation after the test drainage, which ensures the accuracy of the second test and makes the test results more authentic and reliable. The dry method adopts the linear jet dispersion method, and the samples fly vertically backward after being dispersed by high-pressure gas, avoiding the secondary cluster of particles to be tested. Meanwhile, the pipeline design without residue is adopted to ensure the accuracy of testing different samples.GA-2607 unique advantages are highlighted by its excellent optical path automatic proofreading system, dry and wet one-key switching system, dry computer remote control feeding system, etc.

https://www.gonoava.com/product/ga-2607-dry-and-wet-integrated-laser-particle-size-analyzer/

The following products also meet this standard

https://www.gonoava.com/product/ga-2606-b-wet-process-automatic-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2606-a-automatic-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2605-b-intelligent-automatic-wet-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2605-a-automatic-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2604-dry-process-automatic-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2603-spray-laser-particle-size-analyzer/

https://www.gonoava.com/product/ga-2601-spray-automatic-laser-particle-size-analyzer/

Email: [email protected]
WhatsApp: 0086 18670728798(We chat)
If you have any questions you can send me a message or email.