TH9110 Withstanding Voltage Insulation Tester
- Descrizione
- Inchiesta
Descrizione
Withstanding Voltage Tester
Caratteristiche
High power: AC 5kV / 100mA / 500VA output
High security:
High-voltage floating output design, in line with the safety
requirements of EU standards EN50191 (only TH9110)
Electric shock protection function
Alta risoluzione: 7 pollice 800 × 480 punti, Display LCD TFT
Brand-new operation interface, Menù cinese e inglese
ARC detection function
Contact check function (OSC)
Breakdown voltage test function
One-key screen capture function
One-key recording function
Rear panel output function to facilitate automated production line testing
Magazzinaggio: 100 files, fino a 50 steps per file
Withstanding Voltage Tester
Applicazione
Winding devices
Transformers, generators/motors and other products needing high
-power withstand voltage test and analysis, such as different types of
motor stator, rotor and other high parasitic capacitance products
Electronic components
Capacitors, coils, cores, choke coils, filters and so on
Electrical products
Household appliances, information products, audio-visual
equipment, electric heating appliances, lighting equipment
Withstanding Voltage Tester
Parametro tecnico
| Modello | TH9110 | TH9110A | |
| Withstand Voltage Test | |||
| Tensione di uscita | AC | 0.05 – 5kV Load Variance:1% Precisione:1% Risoluzione: 2V | |
| DC | 0.05 – 6kV Load Variance:1% Precisione:1% Risoluzione: 2V | ||
| Current Test Range | AC | 0.001mA – 120mA(Voltage≤4kV);0.001mA – 100mA(Voltaggio>4kV) Precisione:1% Risoluzione:1μA | |
| DC | 0.0001mA – 25mA Accuracy:1% Risoluzione:0.1 μA | ||
| Potenza in uscita | 500VA | ||
| Prova di resistenza d'isolamento | |||
| Tensione di uscita | : 0.05 – 5kV Resolution:2V Accuracy:1% di valore impostato + 0.1% full scale | ||
| Intervallo di prova della resistenza | 1MΩ-50.0GΩ Resolution:0.1MΩ | ||
| Discharge Function | Automatic discharge after the end of the test | ||
| ARC Detection | AC | 1mA – 20mA | |
| DC | 1mA – 10mA | ||
| Contact Check Function | OSC open and short:600Hz, 0.1S | ||
| Security Features | |||
| High Voltage Floating Output | Corrente di dispersione <3 mA | —— | |
| Electric Shock Protection | 0.5mA ±0.25mA | ||
| Other Protection | Start protection, panel operation password protection | ||
| Alarm Indication | PASS: short tone, green light; FAIL: long tone, red light | ||
| Memoria | groups, 50 steps per group | ||
| General Parameters | |||
| Voltage Rise Time | 0.1s — 999.9s | ||
| Test Time Setting(AC/DC) | 0.3s — 999s | ||
| Voltage Fall Time | 0.1s — 999.9s | ||
| Tempo di attesa (IR) | 0.2s — 999.9s | ||
| Time Accuracy | ±(1%+0.1S) | ||