Tonghui TH1951 Digital Multimeter Tester
- Descripción
- Consulta
Descripción
Multímetro digital
Características
TH1951 5 1/2 digit display(119,999 cuenta)
TH1961 6 1/2 digit display(1,199,999 cuenta)
12 different measurement capabilities: DCV/ACV, DCI/ACI,
ohm2W/ohm4W,Frequency/Period, Prueba de diodo, Continuidad, dB/dBm
High brightness vacuum fluorescent display
True-rms AC voltage and current measurement, bandwidth up
to 100kHz(TH1951)/300kilociclos(TH1961)
DCV measurement accuracy up to 0.0035%, resolution up to 0.1uV
máx.. measurement rate: 1000 medida/seg
Equal accuracy frequency measurement up to 1.1MHz
Relative mode(RELACIÓN) to eliminate residual reading
2 W., 4W resistance measurement mode selectable
Built-in mX +b,%, dB, dBm etc. mathematics calculation function
512 readings storage and MAX/MIN/AVER/STD statistics
Hasta 30,000 readings storage(without statistics)
HI/IN/LO comparator function
USB, BPIB and RS-232 Interfaces provide easy system
communication
Calibration without opening the case
10 sets of multimeter setup can be stored and loaded
Multímetro digital
Parámetro técnico
| Test Function | ||||||||||||||
| Test Parameter | ECV, ACV, DCI, ACI, ohm2W, ohm4W, FREQ,PERI DIODE , CONT | |||||||||||||
| Mathematics Function | mX+b, %, dB, dBm, RELACIÓN | |||||||||||||
| Rango | Auto, Manual | |||||||||||||
| Mostrar | VFD | |||||||||||||
| Modo de disparo | INT/MAN/BUS/EXT | |||||||||||||
| Programmable Time Delay | 0 − 6000mS | |||||||||||||
| Reading Storage and Statistics | 2 a 512 readings can be stored, loaded and countedType of statistics: MÁXIMO,MIN,AVER,STD | |||||||||||||
| Espera de lectura | To find out best stable reading for each data block of the given reading number according to the given accuracy. | |||||||||||||
| Limitation Measurement | Para juzgar Hola,EN,LO y pantalla, withALARM for HI/LO | |||||||||||||
| Setup Storage | 10 setup files can be stored and loaded | |||||||||||||
| Calibración | Recommend Fluke5520A with TH1951/TH1961 Accuracy Calibration software( opción ) | |||||||||||||
| Interfaz de comunicación | SCPI command support for GPIB(opcional),RS232(opcional) and USB(estándar) interfaz | |||||||||||||
| Especificaciones | ||||||||||||||
| Condición de medición | ||||||||||||||
| Calibration interval: un añoOperación Humedad:18°C-28°C , ≤90% HR; Cuando el rango de resistencia es de 10M y 100M, ≤70%RHWarming up time: 30 minLa precisión se expresa como: +/-(% de lectura +% de rango)Coeficiente de temperatura: 0°C–18°C & 28°C–40°C,+0.1%×precisión /°CLa siguiente es la especificación en modo lento, Para otros, consulte el manual de operación. . | ||||||||||||||
| Full Scale Reading Digits and Reading Rate (medida/seg) | ||||||||||||||
| Rate | Lento | Con | Rápido | |||||||||||
| TH1951 | TH1961 | |||||||||||||
| Full Scale Reading (dígitos) | 119,999 | 1,199,999 | 119,999 | 11,999 | ||||||||||
| Reading Rate(medida/seg) | DC V,DC I | 4 | 2 | 16 | 57 | |||||||||
| AC V,AC I | 3 | 1.5 | 4 | 25 | ||||||||||
| Ω 2W | 4 | 2 | 16 | 57 | ||||||||||
| Ω 4W | 3 | 1.5 | 10 | 33 | ||||||||||