Описание

Profilometer

пrinciple

The instrument measuring principle for rectangular coordinate measuring method, namely, through the X axis, Z1 shaft sensor, the measured parts of surveying and mapping the surface profile of the coordinates of the point, through the electrical components, will be measured by the sensor the coordinates of the point data transmission to the upper PC, the software of the original coordinate data collected in the survey were mathematical processing, marked with the required engineering survey projects.

Profilometer

Фunction

Profile measurement function:

Размеры: horizontal distance, vertical distance, linear distance, radius, диаметр

Included Angle: includes horizontal Angle, vertical Angle and included Angle

Position tolerance: including parallelism and perpendicularity

Shape tolerance: including straightness, convexity and arc

Contour auxiliary generation: including auxiliary points, auxiliary lines and auxiliary circles

Roughness measurement function:

Roughness features: Ра, рупий, Рв, Рз, Рз (ОН), Р3з, RzDIN, Rzj, Рмакс, Rc, рт, Rq, рупий, Рку, Рсм, рупий, R△ Q, Rk, Rpk, Rvk, Mr1, Mr2, Рмр

Ripple parameters: Wa, Wt, Wp, Wv, Wz, Wq, Wsm, Wsk, Wku, Wmr

Original contour parameters: Па, Пт, Pp, Pv, Pz, Pq, Psm, Psk, Pku, Pmr

Profilometer

Диапазон измерения

Элемент Диапазон измерения Разрешение
Column 320мм –
Driver 100мм 0.2мкм
Тензодатчик 15мм 0.05мкм
Датчик ±420μm 65536:1

Profilome

Техническая спецификация

Some technical parameters of profilometer Linear precision1 ≤±(1.5+|0.2ЧАС|)μm
circular arc2 ≤±(2+R/8)μm
Angle3 ≤±2′
straightness4 ≤0.8μm/100mm
Roughness part technical parameters Linear precision ≤±(7nm+3.5%)
salvage value of noise5 ≤0.025μm
repeatability6 1δ≤2nm
cutoff wavelength 0.025、0.08、0.25、0.8、2.5、8мм
specified length λcX2、3、4、5、6、7
Motion control X axis Drive way электрический
Z axis Drive way электрический
X axis drive speed 0.1~10mm/s
Z axis drive speed 0.5-10мм/с

Примечание: 1. H measures the height; 2, 2мм < р < 10mm standard ball, sampling arc Angle is 120°; 3, 60°, 90° Angle block, corner sampling length is 5mm; 4, λ C is 2.5mm, the measurement speed is less than or equal to 0.3mm/s, the measurement of flat crystal; 5, λ C is 0.08mm, the measurement speed is 0.1mm/s, the measurement of flat crystal; 6. Square wave standard parts with Ra of 0.35-0.5μm are used; 7, the above parameters were measured at 20℃±2℃, the step temperature was not more than 2℃/h and the maximum ground vibration RMS < 50Hz 2.5μm/s and RMS > 50Hz 5.0μm/s.

Profilometer

Profilometer