GA-2009-B Three Box Cold Heat Shock Test Chamber
- Description
- Inquiry
Description
Three Box Cold Heat Shock Test Chamber
Use
Programable thermal shock chamber price is used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time,Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is hightemperature region, another is low-temperatureregion, the testing sample placed on the moving basket, using unique heat storage and cool storage,the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing.
Three Box Cold Heat Shock Test Chamber
Specification
| Model | A
(A~D) |
B
(A~D) |
C
(A~D) |
D
(A~D) |
E
(A~D) |
F
(A~D) |
| Inner size: WHD(cm) | 40*35*30 | 50*30*40 | 50*40*40 | 50*50*40 | 60*40*50 | 60*50*50 |
| External size: WHD(cm) | 150*180*150 | 160*175*160 | 160*185*160 | 160*185*170 | 170*185*170 | 170*195*170 |
| Temperature range(Test Chamber) | high temperature:+60℃~+200℃;low temperature -10℃~-65℃(A:-45℃;B:-55℃;C:-65℃) | |||||
| Heating Time | RT~200℃ About 30min | |||||
| Cooling Time | RT~-70℃ About 85min | |||||
| Temperature Conversion Time | Less than 10S | |||||
| Temperature Recovery Time | Less than 5min | |||||
| Temperature Deviation | ±2.0℃ | |||||
| Temperature Fluctuation | ±0.5℃ | |||||
| Material | External material: SUS#304 Stainless steel plate
Internal material:SUS#304Stainless steel plate |
|||||
| Output Mode | Water-cooled or air-cooled,Taikang compressor in France | |||||
| Controller | TEMI South Korea | |||||
| Cooling System | Water-cooled or air-cooled,Taikang compressor in France | |||||
| Protection devices | Fuse switch, compressor overload switch, refrigerant high and low pressure
protection switch,super humidity over-temperature protection switch, fuse, failure warning system |
|||||
| patrs | Watching window;50mm testing hole; partition plat | |||||
| Power | AC380V 50/60Hz Three-phase four-wire ac power | |||||
| weight (kg) | 750 | 790 | 830 | 880 | 950 | 1050 |
Three Box Cold Heat Shock Test Chamber
| 1. Profile. | |
| 1.1 Item | Thermal shock test chamber (three zone) |
| 1.2 Model | GA-2010 |
| 1.3 Sample restrictions
|
The equipment is prohibited to do the test and storing as below:
– Flammable, explosive, volastile substances; – Corrosive substances; – Biological samples; – Source of strong electromagnetic radiation. |
| 1.4 Test condition | Envrionmental temperature: +25℃; humidity: ≤85%, with no samples inside the chamber |
| 1.5 Test method | GB/T 5170.2-1996 temperature test chamber and so on |
| 1.6 Meet the test standard | Meet GB2423, IEC68-2-14, JIS C 0025, MIL-STD-883E,
IPC 2.6.7, BELLCORE and other standards |
| 2. Technical parameters. | |
| Inner size (WxHxD)mm | 400×350×300mm |
| Inner volume | 42L |
| External size (WxHxD)mm | 1550x1650x 1470mm |
| Preheating temperature | +60℃~+200℃ (heat up +25℃~+200℃∕ 20min) |
| Precooling temperature | -10℃ ~-45℃ (cooling +25℃~-45 ℃∕65min) |
| High temp. shock range | +60℃~+150℃ |
| Low temp. shock range | -10℃~-40℃ |
| Temperature fluctuation | ±0.5℃ |
| Temperature deviation | ±2.0℃ |
| Shock recovery time | ≤5min (control point) |
| Three Box Cold Heat Shock Test Chamber
3. Structure |
|
| 3-1. Inner & External chamber material | Inner / External chamber: stainless steel plate (SUS # 304) |
| 3-2. Main structure design | Divided into low temperature storing area, product testing area, high temperature heat storing area. |
| 3-3. Cooling storage / heating storage material | High efficiency aluminum enable heat storage capacity and super-cold capacity to reach super fast exchanging. |
| 3-4.Environmental conditions | Meet MIL , IEC , JIS ,IPC etc. and the specifications of the chamber |
| 3-6. Testing hole | For connecting external testing wire and signal (10.0cm) of 1 piece |
| 3-7. Table running wheel | Moving position adjustbale and forced fixed knot position (500kg/wheel) |
| 3-8. Thermal insulating layer | Burning fire resistant thermal insulation layer PU + thermal insulation wool (thermal insulation thickness of 12.0 cm) |
| 3-9. Frame inside chamber | Height adjustable grid shelves and stainless steel mesh grid plate (2pcs, separation distance of 5.0cm ) |