KDZD Dielectric breakdown strength tester
- Description
- Enquête
Description
Dielectric breakdown strength tester
Dielectric breakdown strength testerVoltage breakdown tester according to the national GB1408.1-2006 “insulation material electrical strength test method” its role can be called electrical insulation strength tester, dielectric strength tester, etc.. The working principle is that a voltage higher than normal operation is added to the insulator of the device under test for a specified period of time, and the voltage added to the above will only produce a small leakage current, so the insulation is better. The test system consists of three modules: program-controlled power module, signal acquisition and conditioning module and computer control system, with alarm and time control functions.
Voltage breakdown tester is mainly applicable to solid insulating materials (tel que: Plastique, caoutchouc, laminated materials, film, resin, mica, céramique, verre, insulating paint and other insulating materials and insulating parts) in the power frequency voltage or DC voltage breakdown strength and voltage resistance test.
It is widely used in power electronics industry, machinery industry ministry, research institute, military research, insulation material production unit of high voltage breakdown test and design and manufacture.
Dielectric breakdown strength tester
Caractéristiques du produit
1, the device for the touch screen operation control.
2, if you need to perform curve analysis, you can be equipped with a computer, only data and curve recording function, no equipment control, to avoid the test personnel in the computer and equipment alternating operation, more humane.
3, the equipment has the function of memory of test parameters, the same test conditions do not need to be set each test, and the power will still remember the last test set parameters.
4, the test interface is simple and clear, and is equipped with schematic curve description, different parameters, different curve trends, easy to understand.
5, the control panel is simple, the function is clearly marked, l'opération est simple.
6, can record and display 10 test records at the same time, convenient for comparative analysis of test data. Data can be discarded in real time.
7, the equipment test interface adopts the real-time display mode, which is more convenient to watch the test process.
8, the equipment has a safety warning, the test can not start when the test chamber door is not closed, and a warning will pop up, and the warning will pop up at the full degree (c'est: no output of the high voltage transformer), and if the test is opened during the test, the test will automatically end.
9. The equipment is equipped with three-color alarm. (facultatif)
Dielectric breakdown strength tester
| tension | Numéro de modèle | 5Kv | 10Kv | 20Kv | 50Kv | 100Kv | 150Kv |
| 1 | Tension d'entrée | AC220V 50Hz | |||||
| 2 | Tension de sortie | CA:0~5kV; CC:0~5kV | CA:0~10kV; CC:0~10kV | CA:0~20kV
CC:0~20kV |
CA:0~50kV; CC:0~50kV | CA:0~100kV; CC:0~100kV | CA:0~150kV; CC:0~150kV |
| 3 | Puissance de sortie | 0.5kVA | 1kVA | 2kVA | 3kVA | 10kVA | 15kVA |
| 4 | Plage de mesure | CA:0.05~5kV; CC:0~5kV | CA:0.5~10kV; CC:0.5~10kV | CA:1~20kV; CC:1~20kV | CA:1~50kV; CC:1~50kV | AC1~100kV; DC1~100kV | AC1~150kV; DC1~150kV |
| 5 | Measurement error | ≤ 2% | |||||
| 6 | Boost rate | 0.025kV/s~0.5/s | 0.05kV/s~1kV/s | 0.1kV/s~2kV/s | 0.20kV/s~5kV/s | 0.02kV/s~10kV/s | 1kV/s~10kV/s |
| 7 | Withstand voltage time | 0 ~ 4H(no load) | |||||
| 8
9 |
Leakage current | It can be freely configured by computer software | |||||
| Source d'énergie | Ac 220V±10% single-phase AC voltage and 50Hz±1% frequency | ||||||
| 10 | Environnement de test | Température: 15 ~ 30℃, humidité relative: 30% ~ 65% can be stable operation.
|
|||||
| 11 | Overall dimension | Length × width × height: 1000×1000×1400 mm | |||||
| 12 | Dead weight of equipment | 150kg | 300kg | ||||
| 13 | Grounding requirement | The instrument needs to be grounded separately, the grounding is attached to the national standard requirements, and the metal rod should be buried at least 1.5 meters underground | |||||