Transformer Test System

Maikling pambungad

GA200XB is professional transformer comprehensive tester. Can be in 50 feet within the electronic transformers, power transformers, network filters, such as all kinds of transformer performance testing. Using 7 inches LCD TFT display. It is a high-speed, broadband, 6-bit test resolution of the impedance measuring instrument, multi frequency points and 0.05% accuracy can meet the requirements of various occasions’ component parameters detection. It is a high cost of quality testing equipment.

Transformer Test System
Teknikal na Parameter
MGA PAGTUTUKOY

GA200XB/GA300XB/GA500XB Transformer Tester

Mga Parameter | Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, TRUN, TURN ratio, Lk, Phase
Basic Katumpakan 0.05%; DCR, TURN, TURN ratio: 0.1%
Dalas GA200XB:20Hz~200kHz; GA300XB:20Hz~300kHz; GA500XB:20Hz~500kHz
Display Range Z,X,R:0.01mΩ~99.9999MΩ DCR:0.01mΩ~99.9999MΩY, G,B:0.00001µS~99.9999S

C:0.00001pF~9.9999F L:0.00001µH~9999.99H D:0.00001~9.9999 Turn ratio:1:0.001-1000:1

Q:0.00001~9999.9 q(rad): -3.14159 – 3.14159 q(deg): -179.999° -179.999°

Source Resistance 30 Ω, 100 Ω, 10 /100, 10 /CC
Saklaw Auto, Hold, Manual selection
Signal Level 5 mV-2V , Katumpakan:10%; Constant level:10 mV-1 V, Katumpakan:5%; TURN: 5 mV-10V , Katumpakan:10%
DC Bias Source 0V,1.5V,2V,Katumpakan:1%; Option: CKT100mA:±10V(±100mA)
Trigger Mode INT, MAN, EXT, BUS
Bilis 75t/s, 12t/s, 3 t/s
Equivalent Circuit In series and parallel
Result Display Direct,Δ,Δ%,V/I
Pag calibrate Open / short / load
Interface RS232C, USB HOST, USB DEVICE, Headset interface, Foot switch; Opsyonal na: HANDLER,GPIB,LAN interface
Ang iba naman The software version of the instrument can be upgraded and updated by U disk.

Maximum can measure transformer products with 50 pins

PANGKALAHATANG MGA TAMPOK
Power Supply Boltahe: 110V/220V; Dalas: 50Hz – 60Hz

375mm (W) *135mm (H) *350mm (L); 7.5kg

Sukat at Timbang
ORDERING INFORMATION
Mga accessory 20PIN transformer scanning box (manwal na manwal, automatic two optional); Transformer scan control line;

Four terminal test cable; Foot switch; AC Power Cord