GA-9002 Touch Screen Oxygen Index Tester
- Descripción
- Consulta
Descripción
GA-9002 Touch Screen Oxygen Index Tester
Design standard:
GB/T 2406.2-2009
GA-9002 Touch Screen Oxygen Index Tester
Advantages
- Full-color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and issue the sound of beep, eliminating the trouble of manually adjusting the oxygen concentration;
- The stepping proportional valve greatly improves the control accuracy of the flow, and the closed-loop control is adopted. Durante el examen, the oxygen concentration drift program automatically adjusts back to the target value, which avoids the disadvantage that the traditional oxygen index tester cannot adjust the oxygen concentration during the test and greatly improves the test accuracy.
GA-9002 Touch Screen Oxygen Index Tester
Principales parámetros técnicos.
- Using imported oxygen sensor, digital display oxygen concentration without calculation, more accurate and more accurate, rango 0-100%
- Digital resolution: 0.1%
- Precisión de la medición: 0.1 nivel
- The touch screen setting program automatically adjusts the oxygen concentration
- One-key calibration accuracy
- One-bond ratio concentration
- Stable oxygen concentration automatic alarm sound
- With timing function
- Experimental data can be stored
- Query historical data
- Historical data can be cleared
- Optional whether to burn 50mm
- Air source fault prompt
- Oxygen sensor fault prompt
- Tips for wrong connection of oxygen and nitrogen
- Oxygen sensor aging tips
- Standard oxygen concentration input
- Diameter of combustion cylinder can be set (two common specifications are optional)
- Flow regulation range: 0-20l /min (0-1200l /h)
- 20.quartz glass tube: two specifications either (diámetro 75 ㎜ or inner diameter or greater or higher 85 milímetros)
- Gas flow rate in combustion cylinder: 40mm±2mm/s
- 2 Dimensiones totales: 650milímetros * 400 * 830milímetros
- Pressure gauge accuracy 2.5, resolución: 0.01mpa
- The test environment: la temperatura ambiente: temperatura ambiente ~ 40 ℃;, humedad relativa: 70%;
- Input pressure: 0.25-0.3mpa
- Presión laboral: nitrogen 0.15-0.20mpa oxygen 0.15-0.20mpa
- The specimen holder can be used for soft and hard plastics, various building materials, textiles, fire doors, etc.
- Propane (butane) ignition system, the ignition nozzle is made of a metal, the end has Φ 2±1mminner diameter nozzle, can be bent freely.Can be inserted into the combustion tube to ignite the sample, the flame length: 16 4milímetros, the size of 5mm-60mm can be adjusted freely,
- Gas: nitrogen and oxygen for industrial use with purity of > 99%;(the purity of industrial oxygen in user-provided/normal gas stations is generally between 99.2% y 99.3%).
- Requerimientos de energía: AC220 (+10%) V, 50HZ
- Maximum power: 150W.
- Self-supporting material sample holder: it can be fixed in the position of the axis of combustion cylinder and can hold the sample vertically
- Non-self-supporting material sample holder: it can fix two vertical edges of the sample on the frame at the same time (optional/applicable to soft non-self-supporting materials such as textiles).
Tips: when testing oxygen index tester, one bottle of industrial-grade oxygen/nitrogen of no less than 98% should be used as gas source. As the above gas is high-risk transport, it cannot be used as accessories of oxygen index tester, so it can only be purchased from local gas stations of users.(in order to ensure the purity of the gas, please purchase it at a local regular gas station)













