Descripción

GA-9001-B Oxygen Index Tester

Design standard:

GB/T 2406.2-2009 GB/T 2406.1-2008.ASTM D 2863, YO ASI 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996 NB/SH/T 0815-2010 TB/T 2919-1998 CEI 61144-1992 YO ASI 15705-2002 YO ASI 4589-2-1996

GA-9001-B Oxygen Index Tester

Sfrente de aplicación:

It is suitable for the determination of the combustion performance of plastics, goma, fibra, foam plastics, film and textile materials

 

GA-9001-B Oxygen Index Tester

Principales parámetros técnicos.

  1. Using imported oxygen sensor, digital display oxygen concentration without calculation, more accurate and more accurate, rango 0-100%
  2. The built-in temperature controller to control the temperature, the control range: 23 ℃ ±2 ℃
  3. Digital resolution: 0.1%
  4. Precisión de la medición: 0.4 calificación
  5. Flow regulation range: 0-10l /min (60-600l /h)
  6. Tiempo de respuesta: < 5S
  7. High temperature resistant quartz glass tube, diámetro interno 75 ㎜ height 480 mm or more
  8. Gas flow rate in combustion cylinder: 40mm ±2mm/s
  9. Pressure gauge accuracy 2.5, resolución: 0.01mpa
  10. The flowmeter: 1-15 l/min (60-900 l/H) is adjustable, test environment: la temperatura ambiente: temperatura ambiente ~ 40 ℃;, humedad relativa: 70%;
  11. Input pressure: 0.2-0.3mpa
  12. Presión laboral: nitrogen 0.1-0.15mpa oxygen 0.1-0.15mpa oxygen/nitrogen mixed gas inlet: including pressure regulator valve, flow control valve, gas filter and mixing chamber.
  13. The sample holder can be used for soft and hard plastics, textiles, fire doors, etc.
  14. Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely
  15. Gas: nitrogen and oxygen for industrial use with purity of > 99%;(user supplied).
  16. Requerimientos de energía: AC220 (±10%) V, 50HZ
  17. Maximum working power: 50W.
  18. Igniter: made of a metal, end diameter Φ 2 ± 1 mm nozzle, can ignite sample in combustion tube, the flame length: 16 ±4 mm, the size is adjustable
  19. Self-supporting material sample holder: it can be fixed in the position of the axis of combustion cylinder and can hold the sample vertically
  20. Non-self-supporting material sample holder: two vertical edges of the sample can be fixed on the frame at the same time (optional for non-self-supporting materials such as textiles and films).

GA-9001-B Oxygen Index Tester

Chassis and part of the structure:

  1. Control box: CNC machine tool processing molding, electrostatic spraying, hermoso, anti-rust and anti-corrosion.The control part is separately controlled from the test part
  2. The combustion tube: high temperature resistant high quality quartz glass tube (inner ¢75 mm, 480 milímetros) long export inner diameter: phi 40 milímetros
  3. Sample fixture: self-supporting fixture, and can hold the sample vertically;(optional non-self-supporting style frame), two sets of style clips meet different test requirements;Style clip plug type, style and style clip more simple
  4. The end of a long pole igniter tube hole diameter ¢2 ± 1 milímetros, igniter flame length (5 -) 50 mm can be arbitrary adjustable