Descripción

GA-1911 Thermal Conductivity Instrument

Introducción del producto:

Based on the transient plane heat source method (TPS) thermal conductivity tester.The product is independently developed by Achievo Instrument, testing performance

Stable, strong data processing and analysis ability, can be used for the measurement of thermal conductivity of various types of materials.

 

GA-1911 Thermal Conductivity Instrument

Características del instrumento:

Wide range of test, stable test performance, in the domestic similar instrument, in the leading level;

Direct measurement, test time about 5-160s can be set, can quickly and accurately measure the thermal conductivity, saving a lot of time;

It will not be affected by contact thermal resistance as the static method;

No special sample preparation, no special requirements for sample shape, block solid only need relatively smooth sample surface and full length and width at least twice the diameter of the probe;

Non-destructive testing of samples means that samples can be reused;

The probe adopts the double helix structure to design, combined with the exclusive mathematical model, using the core algorithm to analyze and calculate the data collected on the probe;

The structure design of the sample table is clever, fácil de operar, suitable for placing samples of different thickness, and simple and beautiful;

Data acquisition on the probe using imported data acquisition chip, the high resolution of the chip, can make the test results more accurate and reliable;

The control system of the host uses THE ARM microprocessor, which is faster than the traditional microprocessor, improves the analysis and processing ability of the system, and makes the calculation results more accurate;

The instrument can be used for block solid, paste solid, granular solid, colloid, líquido, polvo, revestimiento, película, insulation materials and other thermal property parameters measurement;

Intelligent man-machine interface, color LCD display, control de pantalla táctil, easy and simple operation;

Strong data processing ability.Highly automated computer data communication and report processing system.

 

GA-1911 Thermal Conductivity Instrument

Measurement object:

Material type: metal, cerámico, aleación, ore, polímero, composite, papel, tela, foam (flat surface insulation)

Thermal material, plate), polyurethane, phenolic, urine aldehyde, mineral wool (lana de vidrio, rock wool, mineral wool), cement wall, vaso

CRC strong composite board, cement polystyrene board, sandwich concrete, FRP panel composite board, paper honeycomb board, etc..

 

GA-1911 Thermal Conductivity Instrument

Parámetros técnicos:

  1. rango de prueba: 0.001-300W. /(m*K)
  2. Measuring temperature range: temperatura ambiente — 130℃
  3. Probe diameter: no. 1 probe 7.5mm;No. 2 probe 15mm
  4. Exactitud: 0.001
  5. Tiempo de medición: 5~160 seconds
  6. Fuente de alimentación: CA 220 V
  7. machine power :< 500W8. Sample temperature rise :<15℃
  8. Test sample power P: no. 1 probe power 0<PAG<1 w;No. 2 probe power 0<PAG<20 w.
  9. sample specifications: No. 1 probe sample (≥ 7.5*7.5*3.75mm) No. 2 probe sample (≥15*15*7.5mm)

Nota: No. 1 probe is used to measure low conductivity material with thin thickness.If the sample surface is smooth and sticky, the sample can be put into Line superposition