Ts7x series is a grating spectrophotometer that 3nh company has spent 3 years to design and is developed by 3nh independent intellectual property rights. The instrument adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector, the full spectrum led with high life as the light source, and the optical resolution is less than 10nm in the visible light range.
Under the condition of d/8 geometric optical illumination recommended by CIE, TS7600 grating spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples, and also can accurately measure and express various color difference formulas and color indexes in various color spaces. With spectrophotometer TS7600, it can easily realize the accurate transmission of color and can also be used as the detection equipment of accurate color matching system.
Spectrophotometer TS7600 is also widely used in the color quality control of various products. TS7600 is equipped with high-end color management software, which is connected to the computer to realize more function expansion. The instrument has stable performance, accurate color measurement and powerful function. It is widely used in plastic electronics, paint and coating, textile printing and dyeing, Druckerpapier, Automobil, medizinische Behandlung, Kosmetik- und Lebensmittelindustrie, as well as scientific research institutions and laboratories etc.
TS7700 Tragbares Gitterspektrophotometer
Merkmale:
- D / 8 geometric optical structure, conforming to CIE No.15, GB / T 3978, GB 2893, GB / T 18833, iso7724 / 1, ASTM e1164, din5033 teil7;
- Adopt combined LED light source with high life and low power consumption;
- Customized one 8mm or 4mm aperture ( the flat/ tip measuring aperture can be switched easily, which is suitable for more tested sample)
- Dual optical path system, the optical resolution in the visible range is less than 10nm, which can measure the SCI and SCE spectrum of the sample at the same time;
- Accurate spectrum and lab data, used for color matching and accurate color transmission;
- High hardware configuration: 3.5-inch TFT true color screen, kapazitiven Touchscreen, 1000 line blazed grating, silicon photocell array detector with large photosensitive area, usw;
- USB-Schnittstelle,convenient for expansion of various functions;
- Super dirt resistant and stable standard white calibration board;
- Large capacity storage space, which can store more than 20000 pieces of test data
- 2/10 standard observer’s angle, multiple light source modes, multiple surface color systems, meet various standards of chromaticity indicators, and the needs of various customers for color measurement;
- Camera locating position and Stabilizer cross measurement position;
- PC software has powerful function expansion;
TS7700 Tragbares Gitterspektrophotometer
Spezifikation
| Modell | TS7700 |
| Optische Geometrie | Reflektieren: Von:8°, von:8°(diffuse Beleuchtung, 8-Grad Betrachtungswinkel) |
| SCI (specular component included)/SCE (specular component excluded) ; UV einschließen / excluded UV light source | |
| Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
| Merkmal | double apertures for accurate color analysis and transmission in laboratory |
| It is used for precise color measurement and quality control in plastic electronics, Farbe und Tinte, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
| Größe der Ulbrichtkugel | Φ40mm |
| Lichtquelle | Combined full spectrum LED light source, UV light source |
| Spektrofotometrischer Modus | Flat Grating |
| Sensor | Silicon photodiode array (double row 40 Gruppen) |
| Wellenlängenbereich | 400~700nm |
| Wellenlängenintervall | 10nm |
| Halbbandbreite | 10nm |
| Gemessener Reflexionsbereich | 0-200% |
| Blende messen | MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
| Spiegelkomponente | SCI&SCE |
| Farbraum | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
| Farbdifferenzformel | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Jäger) |
| Anderer kolorimetrischer Index | WI(ASTM E313,CIE/ISO,AATCC,Jäger), |
| TUN(ASTM D1925,ASTM 313), | |
| Metamerie-Index MI, | |
| Färbeechtheit, Farbechtheit, Farbstärke, Opazität, | |
| 8° Glanz,555 tone classification | |
| Beobachterwinkel | 2°/10° |
| Erhellend | D65,A,C,D50,D55,D75,F1,F2(Kuh),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(Tl84),F12(TL83/U30) |
| Angezeigte Daten | Spektrogramm/Werte, Proben von Chromatizitätswerten, Farbdifferenzwerte/Grafik, PASS/FAIL-Ergebnis, Farbversatz |
| Zeit messen | About 1.5s (Measure SCI & SCE about 3.2s) |
| Wiederholbarkeit | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm zu 700 nm: within 0.18%) |
| Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 Zeiten um 5 second intervals after white calibration) | |
| Fehler zwischen Instrumenten | MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Messmodus | Einzelmessung, Durchschnittliche Messung(2-99mal) |
| Ortungsmethode | Camera Locating,stabilizer cross position |
| Abmessungen | L*W*H=129X76X217mm |
| Gewicht | Approx 600g |
| Batterie | 3.7V,5000mAh Li-ion battery, 6000 Messungen innerhalb 8 Std. |
| Lebensdauer des Leuchtmittels | 5 Jahre, mehr als 3 millionenfache Messungen |
| Angezeigte Daten | 3.5-Zoll-TFT-Farb-LCD, Kapazitiven Touchscreen |
| Datenschnittstelle | USB, Bluetooth 4.2 |
| Datenspeicher | Standard 1000 Stck, Probe 30000 Stck |
| Sprache | Simplified Chinese, Englisch, traditional Chinese |
| Betriebsumgebung | 0~40℃, 0~85 % relative Luftfeuchtigkeit (keine Kondensation), Höhe < 2000M |
| Speicherumgebung | -20~50℃, 0~85 % relative Luftfeuchtigkeit (keine Kondensation) |
| Standardzubehör | Netzteil, Benutzerhandbuch, PC-Software(Download from office website), USB cable, Kalibrierungskavität für Weiß und Schwarz, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture |
| Optionales Zubehör | Mikrodrucker, Pulvertestbox |
| Anmerkungen | Die Spezifikationen können ohne vorherige Ankündigung geändert werden. |