YS6060 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6060 has many features, wie 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6060 ideal for color analysis within R&D and laboratory environments.
YS6060 Benchtop Grating Spectrophotometer
Merkmale
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED and xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.
9, Multiple accessories, sample holders, fixation clamp, suitable to more working condition.
10, Big capacity data storage, for 40000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
YS6060 Benchtop Grating Spectrophotometer
Anwendungsindustrie
YS6060 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, Elektronik, Farbe und Tinte, printing, garments, leather, Papier, auto, medizinisch, Kosmetika, Essen, science institutes, laboratories.
Technische Spezifikation
| YS6060 | Spezifikation |
| Optische Geometrie | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) Transmittance: d/0 (SCI⪰ Include UV/Exclude UV) Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Spiegelkomponente | RReflexion SCI&SCE TTransmission SCSCImp;SCSCEspan> |
| Größe der Ulbrichtkugel | Φ 154mm |
| Sensor | 256 Bildelement-Doppelarray-CMOS-Bildsensor |
| Lichtquellengerät | 360nm-780nm Combined LED Lamp, 400nm cut-off, 420nm cut-off, UV Lamp |
| Leuchtmittel | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Spektrofotometrischer Modus | Konkaves Gitter |
| Beobachterwinkel | 2° & 10° |
| Wiederholbarkeit | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm zu 700 nm: within 0.04%) Chromaticity value: Φ25.4mm/SCI, Standardabweichung innerhalb von ΔE*ab 0.02 (When a white calibration plate is measured 30 Zeiten um 5 second intervals after white calibration) |
| Fehler zwischen Instrumenten | Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Wellenlängenbereich | 360-780nm |
| Wellenlängenabstand | 10nm |
| Halbbandbreite | 10nm |
| Reflexionsbereich | 0~200% |
| Blende messen | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive: Φ30mm/Φ25.4mm; |
| Farbraum | CIE-Labor, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, AUS, βxy |
| Farbdifferenzformel | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Angezeigte Daten | Spektrogramm/Werte, Chromaticity Values, Farbdifferenzwerte/Grafik, Pass/Fail Result, Farbversatz |
| Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, HunJäger/span> TUN (ASTM D1925, ASTM 313), VONASTM E31313CIE/ISOSO), MI (Metamerism Index), Färbeechtheit, Farbechtheit, Farbstärke, Opazität, Gardner Index, Pt-Co Index, 555 Index, |
| PC Terminal Software | SQCX |
| Data Storage Capacity | Standard: 5000 Stck; Probe: 40000 Pcs. (One PCS can include both SCI and SCE) |
| Datenschnittstelle | USB & Bluetooth |
| Ortungsmethode | Camera Locating |
| Messmodus | Einzelmessung & Durchschnittliche Messung |
| Screen | 7″ TFT Capacitive Screen-touch Display |
| Light Source Device Life | 5 Jahre, mehr als 3 million times measurements. |
| Stromversorgung | DC 24V, 2A Power Adapter |
| Größe | 370×300×200mm |
| Gewicht | 16kg |
| Sprache | Englisch & Chinesisch |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
| Speicherumgebung | TemTemperatur20~50℃; HumFeuchtigkeit~85~85 %o Condensation) |
| Standardzubehör | White and Black Calibration Board, Checking Green Board, Sample Holder, Φ4mm, Φ8mm, Φ15mm, Φ25.4mm Aperture, Netzteil, USB-Kabel, Benutzerhandbuch, PC-Software |
| Optionales Zubehör | Micro-printer, Transmissive Test Clamp Component |