描述

KGZW-120 Three-phase Power Quality Analyzer

产品介绍
KGZW-120 portable three-phase power quality analyzer is a special portable product for the detection and analysis of power grid operation quality. It can provide harmonic analysis and power quality analysis in power operation, and is equipped with a large capacity memory, which can conduct long-term data collection and detection of power grid operation. 同时, it is equipped with PC application software to upload the collected data to the computer for various analysis.

 

KGZW-120 Three-phase Power Quality Analyzer

产品特点
1, color touch screen display, 易于操作.
2, high-performance lithium battery for a long time power supply.
3, complete three-phase troubleshooting tool: measure the actual parameters of each power system: voltage, 当前的, 频率, 力量, 功耗 (活力), unbalance and flicker, harmonics and interharmonics, capture these events like sudden ups and downs, transients, interruptions and rapid voltage changes.
4, KDZW-120 three-phase power quality analyzer is designed and manufactured with reference to the “GB/T14549-93 power quality public grid Harmonic National Standard” IEC61000-4-31A level standard.
5, can use U disk expansion memory, greatly extend the recording time.

 

KGZW-120 Three-phase Power Quality Analyzer

产品特点:
1, voltage, 当前的, 频率: can measure three-phase voltage, zero line voltage, three phase current, zero line current, 频率, ETC.
2, harmonic measurement: can be measured up to 50 harmonics, the measurement results include each harmonic voltage, harmonic current amplitude, the total distortion of voltage harmonics (total distortion rate), each voltage harmonic/current harmonic content rate; Harmonic spectrum diagram can be displayed.
3, power measurement: can measure three-phase apparent power, active power, reactive power, 功率因数, three-phase electric energy, ETC.
4, three-phase unbalance measurement: can measure three-phase voltage unbalance degree and positive sequence, negative sequence, zero sequence voltage; Three-phase current unbalance degree and positive sequence, negative sequence,
5, zero sequence current, can display voltage vector diagram, current vector diagram.
6, surge current: can record at least 40 surge current events.

7, fluctuation/flicker: fluctuation, short-term flicker, long-term flicker measurement.
8, sudden rise/sudden drop: can record voltage sudden rise, sudden drop events, 取决于 40 events can be recorded.
9. Monitoring and recording: Basic (steady state) power quality parameters can be recorded for a long time, and the recording interval is adjustable from 3 几秒钟 30 分钟.
10, digital oscilloscope: can be used to view the voltage/current signal waveform.
Product Application:
1, front-end troubleshooting: use the screen display to quickly diagnose faults and restore the system to normal work Predictive maintenance: detect and prevent power quality problems before downtime occurs
2, quality of service: Check the power quality at the user’s entry line
3, long-term analysis: detect difficult to find or intermittent failure
4, load study: check the capacity of the electrical system before increasing the load
5. Energy evaluation: Quantitative evaluation of energy consumption before and after transformation to prove the effect of saving equipment

 

KGZW-120 Three-phase Power Quality Analyzer

产品参数
Measurable range

accuracy of measurement
状态
Voltage/current/frequency Three-phase voltage: 10~700V(true RMS)
Neutral line voltage: 1 ~ 70V(true RMS)
Three-phase current: 0〜(true RMS value, optional current sensor)
Neutral line current: 0〜(true RMS value, optional current sensor)
频率: 40~70Hz
电压: ±0.5%
当前的: ±0.5%
频率: ±0.01Hz
The A-phase voltage frequency is used as the measurement frequency
harmonics measurement Voltage harmonics: total harmonics, 1~50 harmonics
Current harmonics: total harmonics, 1-50 harmonics
Voltage harmonics: ±0.1(%F)
Current harmonics: ±1%
power measurement Active power: 0.05~700KW
Apparent: 0.05~700KVA
Reactive power: 0.05~700KVAR
功率因数: 0.00~1.00
Active power: 0.01~10000kWh
Apparent electrical energy: 0.01~10000kVAh
Reactive power: 0.01~10000kVARh
Average power factor: 0.00~1.00
Active work: ±2%
Apparent: ±2%
Reactive power: ±2%
功率因数: Reading ±0.005
Active energy: ±2%
Apparent energy: ±2%
Reactive power: ±2%
Average power factor: Reading ±0.005
three-phase imbalance Fundamental voltage: 10~700V(true RMS)
Fundamental current: 0.5〜(true RMS value)
Fundamental frequency: 40~70Hz
Phase Angle: 0~360o
Unbalance degree: 0.0%~100%
电压 :0.5% 当前的 :0.5%
频率: Reading ±0.01Hz
Phase Angle: Reading ± 0.3o
Voltage unbalance: reading ±0.2 Current unbalance: reading ±0.2
The A-phase voltage frequency is used as the total measurement frequency
monitoring record Recorded parameters: three-phase voltage, three-phase current, zero-line current, voltage harmonics (total harmonics, 1-25 harmonics), current harmonics (total harmonics, 1-25 harmonics), three-phase unbalance, active power, 功率因数, fluctuation, flicker Recording duration = (Maximum number of data that can be recorded on the instrument x Storage interval) /60 minutes Maximum number of data that can be recorded on the instrument = 18635 Storage interval: 3S to 30MIN Recording duration: 15 hours to 388 天 Set the collection interval to 3 秒, can monitor 15.5 小时, set the collection interval to 30 分钟, can monitor 388 天 (3 几秒钟 30 minutes continuously adjustable)
Sudden rise and sudden fall Voltage surges, voltage plunges and temporary power outages A maximum of 40 events can be recorded
fluctuate
fluctuate:0.1%~10.0%
fluctuate:±5%
flickering Short time flicker changes long time flicker Short time flicker measurement error :± 5% Long time flicker measurement error :± 5%
digital oscilloscope Three phase voltage, three phase current, zero line voltage and zero line current instantaneous waveform Maximum sampling frequency: 200千赫
Minimum sampling frequency: 100赫兹
模型
KDZN-OL
尺寸
225×155×150
internal storage
128M bit
display screen 触摸屏, 5.7 inch 320×240 color graphics LCD 电源电压
14.4V(lithium battery)
communication interface
GPRS/LAN
重量
2公斤