描述

KGFJ-K SF6气体分解产物测试仪

产品介绍
KGFJ-K SF6 gas decomposition product tester is mainly used to detect SF6 gas decomposition products, the introduction of high-performance, high-resolution electrochemical sensors, using embedded microcomputer technology, is a high-precision intelligent detection instrument. By detecting the content of SO2 and H2S, the main products of insulation cracking inside the equipment, the early failure of SF6 circuit breakers, transformers, GIS, busbars, bushings, transformers and other electrical equipment can be quickly and accurately identified, which is suitable for electric power, 铁路, 冶金, petrochemical and other industries.
KGFJ-K SF6 gas decomposition products tester Main applications: fault location, routine detection, local discharge monitoring, gas purification/filtration monitoring, fault high-voltage contact inspection, SF6 decomposition products detection, check the production of decomposition products in the switch.

 

KGFJ-K SF6气体分解产物测试仪

产品参数
1, gas measurement range: 二氧化硫:0-100 μl/l
H2S: 0-100 μl/l
HF: 0-10 μl/l (选修的)
一氧化碳: 0-100μl/l
2, 灵敏度: 二氧化硫: ±0.1μl/l M
H2S: ±0.1μl/l
H F: ±0.1μl/l
一氧化碳: ±0.1μl/l
3. 响应时间: 45s
4, 样本: built-in pressure regulator valve, filter, flow meter; 3.6 m sampling pipe and one pressure reducing valve connector.
5, working temperature: -20℃ ~ 50℃
6, power source: 220VAC±10%50Hz, AC/DC dual purpose: overcharge protection, continuous work not less than 10 小时;
7, read out: large LCD graphic display, 解决 0.1% SF6;
8, the size: 258(毫米)×240(毫米)×88(毫米);
9, 重量: 关于 2.4 公斤;
10, output interface: USB2.0 specification;
11, sampling flow: 0.01~1L/min.

 

产品特点
1, long life detection components
2, with fault diagnosis function: according to the concentration of SO2, H2S in the measured gas, automatic fault diagnosis and put forward the corresponding treatment suggestions.
3, no need for color tube, sensor direct measurement
4, 高精度, 良好的重复性
5, built-in pressure regulator and electronic mass flowmeter
6, 大型LCD显示
7, 光, portable and easy to use
8, rechargeable battery power supply, AC and DC dual use
9, fast response, almost no preheating waiting
10, the measurement results are not affected by the ambient temperature