博客

Determination of sulfur content in lubricating oil by Compass-4294 portable energy dispersive X-ray fluorescence spectrometer

Using energy dispersive X-ray fluorescence spectrometer Compass4294 to determine the sulfur content of lubricating oil method, without sample processing, analysis speed, 高精度, good precision, two actual samples were respectively 150ug/g,500ug/g and 800ug/g under the standard concentration of recovery test, the recovery rate is 96.15%~ Six (6) RSDs0.513%102.90%. The linear...

阅读更多...

XRF energy dispersive fluorescence spectrometer EDX6000 nondestructive detection of Pt,金,PD,银,铜,Ni6 elements in platinum products

The fluorescence intensity of Pt and Pd was modified by using the multi-element regression equation of XRF gold standard sample, and the modified fluorescence intensity was substituted into the regression equation as the fluorescence intensity of Au and Ag. The content of Pt,金,PD,银,铜,Ni and other 6 elements in platinum products...

阅读更多...

X-ray energy dispersive fluorescence spectrometer XRF test using steps

Preparation of the Spectrometer a) Energize the instrument, heat the equipment according to the working guide of the instrument, and stabilize the instrument according to the manufacturer's instructions. 乙) Ensure the stability of the test and make the detector stable according to the manufacturer's instructions 2 Calibrate a) Select the reference sample as described...

阅读更多...

X-ray fluorescence Spectrometer FAQ Series 2

Customer frequently asked questions about XRF spectrometer: 1. How to maintain the Energy dispersion XRF ? What should be done with X-ray tubes when sample analysis is not carried out? Mainly spectrometer room constant temperature and humidity (关于 22 度, humidity below 60%), clean environment, stable power supply, avoid vibration. When the...

阅读更多...

国际电工委员会 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (lead, 镉, mercury, hexvalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) -RoHS test procedure

RoHS compliance testing IEC 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (lead, 镉, mercury, hexvalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) -RoHS test procedure Procedure for determination of concentrations of the six substances limited to use in electrical and electronic products (lead,...

阅读更多...