In recent years, people have become more interested in food and various biological materials (such as plants, animal and human tissues, bone paths and fluids). As most of the elements of interest are present in ug /g and ng /g concentrations, great care should be taken to sample these materials to avoid contamination. Contaminating traces and other elements of the sample during sampling may come from the environmental sampling operation itself, including airborne dust and sampling tools. The kinds of pollutants that may come from the laboratory atmosphere are in. The minimum requirement to prevent contamination by airborne dust is to have a clean working area to handle the sample. This can be provided by laminar flow cleaning the air bench or at least by cleaning gloves. Laminar flow purification can never be closed), non-metallic tools and laboratory materials should be used. Some examples are given of the possible alternative source of the reagent from the container. It is necessary to take a special bead pre-field tour to avoid changes in the average sample composition due to water loss. This is often the case with a rich sample of small bright fabrics, where REDOX reactions, fermentation or photochemical reactions may cause changes in the average composition. Such as biopsy samples. Necessary precautions Sample types should be stored in a closed system or frozen immediately after sampling. Also, chemical processes, like hydrolysis,

XRF energy dispersion spectrometer biological sample preparation method

In the process of transportation to the laboratory, if transportation need, the sample should be keep cool (4 ° ℃). Only a few hours. Otherwise, should be frozen. For long-term storage, must carry out deep freezing (low – 18 ℃). Containers made with not wet materials, such as teflon, it is recommended to use high-pressure polyethylene, polypropylene, synthetic quartz. Surface for the pretreatment of the beaker and containers can be done by integrating reagent, such as EDTA solution (1%), and then add in inorganic acid (ultra pure HNO3), and then with double distilled water rinse thoroughly.

Usually heterogeneous biological materials. When handling solid samples, should be dry, preparation before, may require pulverization, homogeneous and homogeneity test sample is measured. Body fluid samples to form suspension or emulsion. For these, must consider the separation or homogenization. All kinds of processing methods of biological materials including dry, freeze-dried, ashing and wet processing digestion.

It is usually dried in an oven or freeze-dried as a method of pre-concentration. Sample before measuring. It is important to control the temperature while the oven is drying. Some plant materials (cabbage, for example) will break down at temperatures higher than 85C. Do not store biological materials at temperatures above 100 ° CDry at temperature. After drying or freeze-drying, the material is next ground and homogenized, then granulated or the equal sample is used for wet digestion (note: biological and geological materials should not be dried in the oven at the same time). The oven should be carefully cleaned before drying the biological material.Ashing is used to remove organic substrate. Ashing methods include dry ashing by heating in a Muffle furnace (at 450-500 ° C) and wet ashing the mixture with oxidizing acids. It is not recommended to ashing the loss of volatile elements in the furnace at 450-500 ° C. Usually

XRF energy dispersion spectrometer biological sample preparation method

Dry ash is preferred for wet ashing with a mixture of acids (e.g. HNO3 + HCI) as it reduces the loss of trace elements and is faster and more rapid. It is often possible to remove organic matter more thoroughly. Wet ashing can be done in the “open air way “, using electric heatApparatus and a round-bottomed flask with or without air-cooled reflux. When reducing the many system errors in the decomposition of organic materials, dissolution is carried out in a PTFE pressure projectile. Pressure decomposition requires small amounts of acid and prevents the loss of volatile elements (e.g. Hg, As, Se, Br, 1). The Loss of Point pressure rounds are strictly limited to a sample weight of 0.5g for safety reasons (note: Read the manual carefully and follow the instructions before using a PTFE bomb. In recent years, wet digestion has been facilitated by the introduction of laboratory microwave digestion technology Thermostats. Microwave energy is absorbed directly by the acid and biomaterials, resulting in faster sample decomposition. The digestion method should be optimized and the recovery rate of elements and the precision of the process should be thoroughly tested. After wet digestion, trace amounts of the metal can be pre-concentrated.

Preparation of biological samples for XRF the simplest method is to crush the material after drying. However, the detection limit is insufficient to determine element concentrations below a few parts per million. In this case, the best to wet digestion, then carries on the preconcentration. The most commonly used water analysis of preconcentration technology can also can be used in biological samples, such as using Chelex resin 100 ion exchange in the form of granular beads, with organic reagent (NaDDTC, for example, APDC DBDTC, PAN) precipitation and strong many transition metal ions to form insoluble chelation. Precipitate was filtered through a membrane or nuclear pore filter dry measurement and took a gram of dried plant material (or about 5 grams of fresh material) was analyzed with 25 ml of nitric acid with high purity nitrogen oxides with high heat until brown smoke disappear (= 40 minutes). Do not pour perchlorate into warm water after cooling (24) in acidic solution) to add 10 ml of 70% perchloric acid, and will be heated to again to colorless transparent solution (= 40 minutes). After cooling, add 25 ml of diluent double distilled water, using gaseous NH3 pH adjustment to about 5. This is accomplished by placing a beaker filled with dryer in the solution at the bottom of the concentrated ammonium hydroxide. If fresh dryer used in ammonia, pH adjustment takes about an hour. In the process, please check every 15 minutes with pH test paper measured pH value inBetween 3.5 to 6.0. Preconcentration used to determination of trace metals (Fe, zinc, Cu, Pb, Ni), using NaDDTC solution precipitation of metal ions. Cadmium can add carrier (10 ml of 10 PPM solution) to facilitate the quantitative precipitation. Usually add 10 to 15 ml of 2% NaDDTC aqueous solution (fresh), then get the precipitation let stand for about 20 minutes. Will form the sediment filter through nuclear pore filter, drying and direct measurement. Digestion mixture containing 10 grams of sodium molybdate (as catalyst), the double distilled water soluble in 150 ml and 150 ml – H2SO4 (cone). After cooling, 200 ml of 70% perchlorate. 1 g freeze-dried or 5 grams of fresh blood or tissue volume (150 ml) in the round bottom flask and 40 ml digestion mixture. And then the mixture and the sample under the temperature of 160 ℃ heat about 1 hour. The solution obtained should be clear. After cooling (do not pour perchlorate into warm) in acidic solution and diluted six times, the solution should be boiled to remove chlorine. After cooling, with gaseous NH3 to about 5 methods (see above). Used for the preconcentration of trace metals using NaDDTC solution was developed for the determination of metal ions (Fe, zinc, Cu, Pb, Ni) precipitation (Fe, zinc, Cu, Pb, Ni) precipitation. Cadmium can add carrier (10 ml of 10 PPM solution) to facilitate the quantitative precipitation.

XRF energy dispersion spectrometer biological sample preparation method

Usually add 10 to 15 ml of 2% NaDDTC aqueous solution (fresh), and then proceeds to make deposits to let stand for about 20 minutes. Will form the sediment filter through nuclear pore filter, drying and direct measurement