TH2810D Digital Inductance Meter TH2811D
- Description
- Inquiry
Description
Inductance Meter
Features
100Hz,120Hz,1kHz,10kHz 4 typical test frequencies
4.3 inch TFT liquid crystal display, Chinese and English
optional operation interface
6-digit reading resolution
Maximum test speed:12.5ms, support low frequency and high
speed:TX4+3ms
10 bins sorting, test sorting is more perfect
100 sets of LCRZ instrument setting files, 10 measurements
Soft power switch
Support 110V/220V two power supply voltages
10-point list sweep, support multi-frequency test sorting
Ultra-low signal source output offset (<100μV), meeting the
needs of large inductor, common mode choke inductor test
Super impact protection
Power on state lock button;
Empty fixture judgment
Data logging function
Screen capture function
Interface function, timing, trigger delay, etc. are more complete
Inductance Meter
Technical Parameter
| Model | TH2810B+ |
| Basic Accuracy | 0.1% |
| Test Frequency | 100Hz,120Hz,1kHz,10kHz |
| Test Parameters | L, C, R,Z|, D, Q, X, θd, θr, Vm, Im, % |
| V/I Monitor | Yes |
| AC Test Signal Level | 0.1Vrms,0.3Vrms,1Vrms |
| Signal Source Internal Resistance | 10Ω, 100Ω |
| Test Terminal Configuration | 5-terminal |
| Test Speed(ms/time) | Fast: 19ms; Medium:83ms; Slow: 333msF≤120Hz Fast :4XT+3ms |
| Zero Clearing | Open, Short, Load |
| List Sweep | 10-point list sweep; Each scan point can be individually sorted, support multi-frequency combined test sorting; Scanning test for frequency and AC voltage |
| EquivalentCircuit | Series, Parallel |
| Range Mode | AUTO, HOLD |
| Trigger Mode | Internal, External, Manual, Bus |
| Average Times | 1-255 |
| Arithmetical Operation | Direct reading, ABS,% |
| Delay | Trigger delay, step delay: 0—60.000s, 1ms step |
| General Function | Series, parallel equivalent mode, calibration: open circuit, short circuit, range selection: automatic, manual, trigger mode: INT, MAN,EXT, BUS, keyboard lock function |
| Comparator | 10 bins sorting,BIN1-BIN9,NG,AUX; Bin count function PASS, FALL front panel LED display |
| Nonvolatile Storage | 100 sets of LCRZ instrument setting files, 10 test results |
| External USB Storage | Instrument setting file, CSV data file |
| Model | TH2810D | TH2811D |
| Measurement Function | ||
| Test Parameter | L-Q, C-D, R-Q,Z|-Q | |
| Basic Accuracy | 0.1% | 0.2% |
| Equivalents Circuit | Series, parallel | |
| Mathematical Functions | Deviation and PercentDeviation | —— |
| Rang Mode | Auto, Hold | |
| Trigger Mode | Internal, Manual andExternal | Internal |
| Measurement Speed | Fast: 12, Med: 5.1, Slow: 2.5 (meas/ sec) | |
| Correction Function | Open/Short multi-frequency Zeroing | |
| Measurement Terminals | Five Terminals | |
| Test Signal | ||
| Test Frequency | 100Hz,120Hz,1kHz,10kHz,Accuracy 0.01% | |
| Operation Temperature & Humidity | 0°C – 40°C, ≤90%RH | |
| Power Requirements | Voltage | 99V – 121V, 198V – 242V |
| Frequency | 47.5Hz – 63Hz | |
| Power Consumption | ≤20 VA | |
| Dimensions (W×H×D) | 270mmx130mmx300mm | |
| Weight | Approx. 3.7kg | |