HC-6250 6350 Cable harness testers
- Description
- Inquiry
Description
Cable harness testers
Wire tester/Wire tester is suitable for all kinds of connection lines, connectors, A/V audio/video connection lines, AC/DC plug connection money and other products on the production line testing or the above parts buyers feed inspection
Cable harness testers
|
||||||||||
| Test item | ||
| item | symbol | Range of measurement |
| Break/short circuit | O/S | 2KΩ~50KΩ |
| Instant short break test | 2KΩ~50KΩ | |
| Short-circuit end point judgment | ||
| Conduction test | COND | Max.50.0Ω |
| Intermittent Cond. | Max.50.0Ω | |
| Resistance test | R | Max.1MΩ |
| Capacitance test | C | 10pF~1uF |
| Diode test | D | 0-7V |
| Insulation resistance | IR | 1MΩ~1000MΩ |
| Unilateral test. Point test. Sequential testing | ||
| High voltage test (limited to 8689FA model) | Hipot | Max.5mA |
| 6250.Technical specification | |
| Advanced function
Basic accuracy Test scan mode Measurement time |
Programmable continuous testing
Automatic spot finding self-diagnosis Self-correcting to zero DCR±5% IR ±5% Automatic/short-circuit scan can be switched 0.1 SEC base value |
| Measure frequency and signal
Dc high voltage Ac high voltage Insulation test |
200~1000Vdc 100~700Vac(FA model only) 1M~500M |
| Display/sound device | 320×240 resolution graphic LCD display
6 digit number display number Pass/Fail LED Red/Green indicator/screen display/Sound |
| Measure the contact | 128 Measure the contact
256 contacts available High voltage correction output (+/-) Automatically find a terminal |
| Control panel
screen |
System/Quick/Edit/Function button group
RS-232 communication port Printer port Remote control port |
| Memory device | Flash memory
Up to 62 sets of test Settings files can be stored |
| Power supply
attachment
|
115/230 Vac voltage input ±10%
60/50 Hz Automatically find a probe Horn fixture plate Fixture line Power cord User manual |
| Temperature and humidity | 15ºC~35ºC
Relative humidity RH≦75% |
| Dimensions (W x H x D)
weight Wire specification requirements |
425×190×350 mm Approx. 14Kg (without accessories) Up to 1µF |
| Ordering information HC-6250FA HC-6250N |
200~1000Vdc, 100~700Vac, 200~700Vdc R:1 Mω, IR:1 Mω to 1000 Mω Select 256 test points Horn fixture plate Fixture line (30cm) Check fixture set |