Principle of instrumental measurement

Using radius measurement method, workpiece rotation. High precision air floating spindle is used as reference. Using imported precision circular grating, precision inductance displacement sensor and computer components. Measure the Angle and radial displacement of the measured workpiece to ensure the accuracy of the angular displacement and radial value of the measured workpiece; The measurement software adopts CA system measurement software based on Chinese Windows operating system platform to complete data collection, data processing and printing.

Cylindricity Measuring Instrument

Measurement functions

Measuring function: cylindricity meter, roundness, straightness, coaxiality, concentricity, end runout, end runout, verticality, parallelism, flatness

Analysis functions: surface waviness, spectrum analysis, wave height analysis, adjacent chip runout, segment difference

Roundness evaluation method (4 kinds) : minimum area method, least square method, minimum circumscribed circle method, maximum circumscribed circle

Roundness filtering method: 1, 1-500, 1-150, 1-50, 1-15, 15-500

Waviness filtering: 3-16, 3-17, 15-500, 17-100

Filtering form: Gaussian (ISO standard)

Cylindricity Measuring Instrument

Use requirement

Air compressor air source pressure: 0.45 ~ 0.80Mpa

Air compressor air source flow: ≥0.2m3/min

Power requirement: about 500W; Ac 220V±10%, 50Hz

Environmental requirements: temperature: 10 ~ 30℃; Relative humidity: < 85%

There is no obvious vibration source at the installation site

Separate ground

Cylindricity Measuring Instrument

Technical specification

Item Specification
Measure range Max diameter Ф400mm
Min inner diameter ф3mm
Max height 550mm
Accuracy of principal axis radial error ±(0.025+5H/10000)μm
axial error ±(0.025+6X/10000)μm
 

Parallelism between axis of rotation and z-axis guide rail

2μm/400mm(Busbar benchmark)
workbench Mesa diameter Φ200mm
swing diameter Φ420mm
load capacity 60Kg
adjustment range Adjustable eccentric±2mm ; Adjustable level±1°
rotational speed 0-12 rpm(adjustable)
Column Straightness (narrow range) 0.5μm /100mm
Straightness (full range) 0.8μm /400mm
horizontal arm Horizontal travel distance 180mm
Move speed 0.5-6mm/s OR MANUAL
Sensor Stroke 500μm (Radius difference)
resolution 0.005μm
Needle shape Ruby ball probe(diameter 2mm)
Sensor direction/adjustment Angle either direction/±45°
data collection Imports grating 14400 point/week
magnification Any to a maximum of 200,000 times

 

Parameter

(Product) (Packing) Weight(Wt.kg) Volume(CBM m³)
Lx Ly Lz Wt(kg) Lx Ly Lz Wt(kg)
960 650 1550 240 1000 750 1650 50 290 1.23

Cylindricity Measuring Instrument

Principle of instrumental measurement

Using radius measurement method, workpiece rotation. High precision air floating spindle is used as reference. Using imported precision circular grating, precision inductance displacement sensor and computer components. Measure the Angle and radial displacement of the measured workpiece to ensure the accuracy of the angular displacement and radial value of the measured workpiece; The measurement software adopts CA system measurement software based on Chinese Windows operating system platform to complete data collection, data processing and printing.

Cylindricity Measuring Instrument

Measurement functions

Measuring function: cylindricity meter, roundness, straightness, coaxiality, concentricity, end runout, end runout, verticality, parallelism, flatness

Analysis functions: surface waviness, spectrum analysis, wave height analysis, adjacent chip runout, segment difference

Roundness evaluation method (4 kinds) : minimum area method, least square method, minimum circumscribed circle method, maximum circumscribed circle

Roundness filtering method: 1, 1-500, 1-150, 1-50, 1-15, 15-500

Waviness filtering: 3-16, 3-17, 15-500, 17-100

Filtering form: Gaussian (ISO standard)

Use requirement

Air compressor air source pressure: 0.45 ~ 0.80Mpa

Air compressor air source flow: ≥0.2m3/min

Power requirement: about 500W; Ac 220V±10%, 50Hz

Environmental requirements: temperature: 10 ~ 30℃; Relative humidity: < 85%

There is no obvious vibration source at the installation site

Separate ground

Technical specification

Item Specification
Measure range Max diameter Ф400mm
Min inner diameter ф3mm
Max height 550mm
Accuracy of principal axis radial error ±(0.025+5H/10000)μm
axial error ±(0.025+6X/10000)μm
 

Parallelism between axis of rotation and z-axis guide rail

2μm/400mm(Busbar benchmark)
workbench Mesa diameter Φ200mm
swing diameter Φ420mm
load capacity 60Kg
adjustment range Adjustable eccentric±2mm ; Adjustable level±1°
rotational speed 0-12 rpm(adjustable)
Column Straightness (narrow range) 0.5μm /100mm
Straightness (full range) 0.8μm /400mm
horizontal arm Horizontal travel distance 180mm
Move speed 0.5-6mm/s OR MANUAL
Sensor Stroke 500μm (Radius difference)
resolution 0.005μm
Needle shape Ruby ball probe(diameter 2mm)
Sensor direction/adjustment Angle either direction/±45°
data collection Imports grating 14400 point/week
magnification Any to a maximum of 200,000 times

 

Parameter

(Product) (Packing) Weight(Wt.kg) Volume(CBM m³)
Lx Ly Lz Wt(kg) Lx Ly Lz Wt(kg)
960 650 1550 240 1000 750 1650 50 290 1.23

Cylindricity Measuring Instrument