คำอธิบาย

GA-3805 Solid Liquid Densimeter

การแนะนำ

The solid-liquid densitometer is used in the density test of rubber and plastic industry, อุตสาหกรรมเคมี, powder metallurgy industry, food industry, powder industry and so on.The main representative products are rubber, พลาสติก, ผงโลหะวิทยา, flavor and fragrance, chemical liquid, flux, ฯลฯ. Mdj-300m multifunctional density meter can realize the density test of solid liquid.

Test type: non-absorbent solid, paste: เช่นยาง, พลาสติก, pearl cotton, alloy, powder metallurgy finished products, compact ceramics, magnetic materials finished products, sealant, asphalt glue, gemstone, rock, PVC/PE/PP/ABS/PPS and other granule.

Various liquid densities and concentrations: กรดซัลฟิวริก, sodium hydroxide, ethanol, เมทานอล, potassium hydroxide, ฯลฯ.

ทดสอบ rinciple: it conforms to GB/T1033, กิกะไบต์/T2951, GB/T3850, กิกะไบต์/T533, GB/T208, GB/T5163, กิกะไบต์/ที 1933, GB/T4196, GB/T4123, กิกะไบต์/ที 611, GB/T11540, GB/T12206, GB/T5518 and other standard

 

GA-3805 Solid Liquid Densimeter

pecifications

แบบอย่าง: GA-3805

Weighing range :0.005-300ก

ความแม่นยำของความหนาแน่น :0.001 g/cm

ช่วงความหนาแน่น :0.001~99.999g/cm3

Solid mode: arbitrarily shaped solid block, granular body

Liquid mode: Any fluid can be measured

Principle of measurement: The principle of Archimedes permutation. The test time is about 5 วินาที

The results showed that the density and volume of solids;Liquid density, concentration %, baume Be

Parameter setting: แข็ง: water temperature setting, medium liquid density setting;ของเหลว: specific gravity hammer density setting, density upper and lower limits set

Correction mode: automatic correction with one key

โหมดเอาท์พุต :RS-232C standard communication interface, convenient for test data output and printing

แหล่งจ่ายไฟ :เอซี ~ 220V / 50เฮิรตซ์ (outlet power supply needs to be customized, and it can be noted before ordering)

 

GA-3805 Solid Liquid Densimeter

Solid measurement steps:

Put the product into the measuring table, measure the weight in the air, press ENTER to remember.

(2) Put the product into the water to measure the weight of the water, press ENTER to remember, display the density value.

 

GA-3805 Solid Liquid Densimeter

Liquid measurement steps:

(1) Place the beaker containing the sample on the measuring board and deduct the weight of the hook.

(2) Put the standard weight into the liquid to be measured with a hook and hang it on the measuring stand to display the density value.