คำอธิบาย

การแนะนำเบื้องต้น:

การแนะนำเบื้องต้น:
1, the test Angle is designed and manufactured according to the national standard GB4706.1-2005 (IEC60335-1:2004) chapter 11 “heating” test requirements.
2, the test Angle is mainly used for various electrical and electrical products temperature rise test to provide environmental conditions that meet the standard requirements for temperature rise test. According to the actual test samples can be customized with different distribution specifications, number of temperature measurement points and dimensions of the test Angle.

Technical specification

ขนาด 600X600X1000mm, 800X800X1000mm (or other size)
thermocouple diameter less than 0.3mm thermocouple, K type T type J type (choose one)
thermocouple layout all lead to a wiring bar (or optional thermocouple plug and socket)
temperature measuring copper sheet diameter 15mm, thickness 1mm brass sheet
temperature points 20 คะแนน, 32 คะแนน, 48 คะแนน (or other requirements)
temperature measurement point layout 100X100mm or 76X76mm square (or according to other agreed requirements)
plywood thickness of about 20mm plywood, the front is coated with matt black paint, the back is pasted with gray film board
the moving part the bottom is installed with 4 moving wheels, the total height is about 100mm
The patrol temperature system needs to be equipped separately (48 circuit patrol temperature table is optional)
ขนาด 600X600X1000mm, 800X800X1000mm (or other size)
thermocouple diameter less than 0.3mm thermocouple, K type T type J type (choose one)
thermocouple layout all lead to a wiring bar (or optional thermocouple plug and socket)
temperature measuring copper sheet diameter 15mm, thickness 1mm brass sheet
temperature points 20 คะแนน, 32 คะแนน, 48 คะแนน (or other requirements)
temperature measurement point layout 100X100mm or 76X76mm square (or according to other agreed requirements)
plywood thickness of about 20mm plywood, the front is coated with matt black paint, the back is pasted with gray film board
the moving part the bottom is installed with 4 moving wheels, the total height is about 100mm
The patrol temperature system needs to be equipped separately (48 circuit patrol temperature table is optional)

Technical specification

รายการ พารามิเตอร์ทางเทคนิค (L X W X H unit: มม)
Conventional size 600X600X600 (1000) 800X800X1000 (1200) 1000 x 1000x 1400
Number of locations 25 (9+8+8) 108 (36+36+36) 75 (25+20+20)
Distribution mode 100 x 100±10 100 x 100±10 100 x 100±10
Distribution mode UL 76×76±5 76×76±5 76×76±5
Thermoelectric couple American OMEGA Type K or J thermocouple, เส้นผ่านศูนย์กลาง< ที่ 0.3 มม
Temperature accuracy Actual welding accuracy of thermocouple: ±0.3℃ MAX
Test copper วัสดุ: Brass, diameter 15mm thickness 1mm
Surface treatment Dull black paint
Temperature system Customer’s own temperature monitor or add LCD touch temperature monitoring system
รายการ พารามิเตอร์ทางเทคนิค (L X W X H unit: มม)
Conventional size 600X600X600 (1000) 800X800X1000 (1200) 1000 x 1000x 1400
Number of locations 25 (9+8+8) 108 (36+36+36) 75 (25+20+20)
Distribution mode 100 x 100±10 100 x 100±10 100 x 100±10
Distribution mode UL 76×76±5 76×76±5 76×76±5
Thermoelectric couple American OMEGA Type K or J thermocouple, เส้นผ่านศูนย์กลาง< ที่ 0.3 มม
Temperature accuracy Actual welding accuracy of thermocouple: ±0.3℃ MAX
Test copper วัสดุ: Brass, diameter 15mm thickness 1mm
Surface treatment Dull black paint
Temperature system Customer’s own temperature monitor or add LCD touch temperature monitoring system