KG-703 Oleic Acid Value Tester

Внедрение продукции
The Karl-Fischer Coulometric titration method is the most reliable method for the determination of trace moisture in different substances. This model of automatic trace moisture tester successfully applied this method, adopted advanced automatic control circuit, appearance structure is novel, so that the instrument work more reliable, удобнее. Its analysis speed is fast,
Простое управление, высокая точность, strong automaticity and so on. Widely used in petroleum, химический, электроэнергия, Железнодорожный, pesticide, лекарство, environmental protection and other departments.
The reaction formula of Karl Fischer’s reagent with water is:
I2 + SO2 + 3C5 H5 N + H2O -→ 2C5 H5 N•HI + C5 H5 N•SO3 ……… (1)
C5 H5 N•SO3 + CH3OH -→ C5 H5 N•HSO4CH3 ……………… (2)
The reagent solution used is a mixture of dominant iodine and sulfur dioxide filled with arsenic, метанол, и т. д.. Iodine is formed on the anode by electrolysis, and the iodine produced is, according to Faraday’s law, directly proportional to the amount of charge. As follows:
2I¯+ 2e -→ I2 ………………………… (3)

It can be seen from equation (1) that the number of moles of iodine participating in the reaction is equal to the number of moles of water. The sample is injected into the electrolyte, the water in the sample participates in the reaction, and the iodine consumption in the reaction process can be reflected through the instrument, and the iodine consumption can be calculated according to the electricity used in the electrolysis of the same amount of iodine, and the measured water component is directly displayed on the liquid crystal display. The instrument adopts electrolytic current automatic control system, the size of the electrolytic current can be automatically controlled according to the content of water in the sample, the maximum can reach 400mA. In the electrolysis process, the water is gradually reduced, and the titration speed is correspondingly reduced until the electrolytic end point control loop is opened. This system guarantees high precision, sensitive valves and high speeds during analysis. Кроме того, in the measurement process, it is inevitable that some interfering factors will be introduced, such as the intrusion of moisture from the air, so that the titration tank absorbs moisture and generates blank current. Однако, since the instrument has the function of storing blank current, the number displayed on the display screen is the true water content of the sample being tested.

 

KG-703 Oleic Acid Value Tester

Параметры продукта
Titration method: Coulometric titration (Coulomb analysis)
Отображать: 5.6-дюймовый цветной сенсорный экран (ЖК-дисплей)
Electrolytic current control: 0 ~ 400mA automatic control
Диапазон измерения: 1ug ~ 200mg
Spirit valve: 0.1µg H2O
Точность: 10µg ~ 1000µg±3µg
Not more than 0.3% above 1mg
Нажимать: сенсорный экран + physical button
Connecting machine: can transfer data with balance and computer
Принтер: Micro thermal printer
Источник питания: 220В±10%, 50Гц
Power rate: < 40Вт
Температура окружающей среды: 5 ~ 40ºC
Влажность окружающей среды: ≤ 85%
Размер: 320×280×200
Масса: About 2.5kg

 

KG-703 Oleic Acid Value Tester

Особенность

1) Adopt 32-bit embedded microprocessor as the main control core and embed mini operating system.
2) High constant current detection accuracy, Быстрая скорость измерения, стабильный и надежный.
3) Real-time electrolysis curve to observe the state of the reagent at any time
4) 12 kinds of analysis methods can save 6 common analysis methods to meet customer needs.
5) Full numeric keypad, data can be entered at any time, data calculation is convenient and fast.
6) The host is equipped with automatic discharge and filling function, which greatly improves the working environment. (необязательный)
7) Records with time are more convenient to find.