Product structure
The KDSL-82 high current generator (current riser) belongs to a mobile structure, which is composed of an instrument indicator board and an operating panel. The indicator board is divided into large and small range selection switch (button switch), the green indicator refers to the power signal, the red indicator refers to the working signal. The operation panel consists of a start button (green), a stop button (red), and a work system. It has the characteristics of reasonable structure, красивый внешний вид, light weight and convenient movement.
KDSL-82 high current generator is a current source used as a test, the high current tester uses ARM chip to control the output process and a large capacity ring transformer, and is equipped with a LCD display meter, while displaying the first and second current, ratio and stopwatch contact (or potential) action time. External aluminum alloy chassis, PC panel, with beautiful appearance, large output capacity, маленький размер, light weight and so on.
It is mainly suitable for CT ratio of power system, contact resistance and other occasions that need high current test. For electrical thermal stability, dynamic stability test of low voltage and high current power supply, such as air circuit breaker, contactor, relay temperature rise test and trip.
When the single-phase high-current generator measures the three phases, it should be divided into phases.
Three-phase high-current generator is mainly used for testing three-phase electrical products, and can also be used to test single-phase electrical products. The control scheme of the three-phase and single-phase high-current generator is the same, but the three-phase high-current generator outputs three-phase current.
The high current generator consists of three parts: трансформатор, voltage regulator and control.
Working hours: short working hours
Rated output time: working time is 2.5 минуты;
1/2 rated output time: working time is 30 минуты;
1/3 rated output time: working time is 40 минуты;
1/4 rated output: long-term use;
current generator
Output current A 0 to 4000A
Output voltage V 0 ~ 6V adjustable
Output capacity kVA 12кВА
Primary current range A 0 ~ 2000A, разрешение: 0.1А
Secondary current range A 0 ~ 24A, разрешение: 0.001А
Current resistance timing range S 0 к 9999
Impact timing range m 0 к 999
Текущая точность % 0.5%, 0.2% (Ф.С.)
Working power supply voltage V 220V/380V±10%
Frequency Hz 50Hz±1
Примечание: 1, current 4000A above split type, can be designed and produced according to user requirements. 2, 10000A or more order production.