GA-9001-B Oxygen Index Tester
- Описание
- Расследование
Описание
GA-9001-B Oxygen Index Tester
Дesign standard:
ГБ/Т 2406.2-2009 GB/T 2406.1-2008.ASTM D 2863, ИСО 4589-2, NES 714 ГБ/Т 5454 ГБ/Т 10707 ГБ/Т 8924-2005 ГБ/Т 16581-1996 NB/SH/T 0815-2010 TB/T 2919-1998 МЭК 61144-1992 ИСО 15705-2002 ИСО 4589-2-1996
GA-9001-B Oxygen Index Tester
Скопия заявления:
It is suitable for the determination of the combustion performance of plastics, резина, волокно, foam plastics, film and textile materials
GA-9001-B Oxygen Index Tester
Основные технические параметры
- Using imported oxygen sensor, digital display oxygen concentration without calculation, more accurate and more accurate, диапазон 0-100%
- The built-in temperature controller to control the temperature, the control range: 23 ℃ ±2 ℃
- Digital resolution: 0.1%
- Точность измерения: 0.4 grade
- Flow regulation range: 0-10l /min (60-600l /h)
- Время отклика: < 5С
- High temperature resistant quartz glass tube, inner diameter 75 ㎜ height 480 mm or more
- Gas flow rate in combustion cylinder: 40mm ±2mm/s
- Pressure gauge accuracy 2.5, разрешение: 0.01mpa
- The flowmeter: 1-15 l/min (60-900 l/H) is adjustable, test environment: температура окружающей среды: комнатная температура ~ 40 ℃;, относительная влажность: 70%;
- Input pressure: 0.2-0.3mpa
- Рабочее давление: nitrogen 0.1-0.15mpa oxygen 0.1-0.15mpa oxygen/nitrogen mixed gas inlet: including pressure regulator valve, flow control valve, gas filter and mixing chamber.
- The sample holder can be used for soft and hard plastics, текстиль, fire doors, и т. д.
- Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely
- Gas: nitrogen and oxygen for industrial use with purity of > 99%;(user supplied).
- Требования к питанию: AC220 (±10%) В, 50ХЗ
- Maximum working power: 50Вт
- Igniter: made of a metal, end diameter Φ 2 ± 1 сопло мм, can ignite sample in combustion tube, the flame length: 16 ±4 mm, the size is adjustable
- Self-supporting material sample holder: it can be fixed in the position of the axis of combustion cylinder and can hold the sample vertically
- Non-self-supporting material sample holder: two vertical edges of the sample can be fixed on the frame at the same time (optional for non-self-supporting materials such as textiles and films).
GA-9001-B Oxygen Index Tester
Chassis and part of the structure:
- Control box: CNC machine tool processing molding, electrostatic spraying, красивый, anti-rust and anti-corrosion.The control part is separately controlled from the test part
- The combustion tube: high temperature resistant high quality quartz glass tube (inner ¢75 mm, 480 мм) long export inner diameter: phi 40 мм
- Sample fixture: self-supporting fixture, and can hold the sample vertically;(optional non-self-supporting style frame), two sets of style clips meet different test requirements;Style clip plug type, style and style clip more simple
- The end of a long pole igniter tube hole diameter ¢2 ± 1 мм, igniter flame length (5 -) 50 mm can be arbitrary adjustable