- Описание
- Расследование
Описание
GA-3816 Измеритель толщины покрытия
Введение
The Times GA-3816 thickness gauge is a portable measuring instrument, which can measure the thickness of coating and coating rapidly and precisely without damage.It can be used in both laboratory and engineering field.Through the use of different probe, can meet the needs of a variety of measurement.Scope of era GA-3816 thickness gauge using both the magnetic and eddy current thickness method, measuring magnetic metal substrate condition (such as steel, железо, alloy and hard magnetic steel, и т. д.) on the magnetic coating thickness (such as aluminum, хром, медь, эмаль, и т. д.), резина, paint and nonmagnetic metal substrate (например, медь, алюминий, цинк, олово, и т. д.) on the conductive layer thickness.
GA-3816 Измеритель толщины покрытия
Character and function
Using both magnetic and eddy current thickness method, and F type measuring head without damage to the measurement of magnetic metal basic body of magnetic coating thickness (such as steel, железо, zinc alloy and hard magnetic steel, алюминий, хром, медь, резина, краска, и т. д.), and N type measuring head without damage to the measurement of non-magnetic thickness of the conductive coating on metal substrates (например, медь, алюминий, цинк, tin and other metal oxide film of paint, резина, пластик, и т. д.)
Can use 6 kinds of measuring head / 90 ° F400, Ф1, Ф1, F10, N1, CN02
Two measurement methods: CONTINUE and SINGLE
Two ways of working: DIRECT and group (APPL)
There are five statistics: MEAN, larger (МАКС), MIN, number of tests (NO.), and standard deviation (S.DEV).
Two methods can be used to calibrate the instrument
Chinese and English menu display, operation more intuitive and convenient
Liquid crystal display has backlighting function
Он может хранить 640 данные
With delete function, delete single or all data measured
Функция печати
With integrated printer, легко использовать
Power supply undervoltage indication
The operation process is beeping (single measurement method)
Error message function
Manual and automatic shutdown functions
GA-3816 Измеритель толщины покрытия
TT270 thickness gauge head selection table is as follows:
| Probe model | F400 | Ф1 | F1/90° | F10 | |||
| Work Theory | Magnetic induction | ||||||
| Test range(um) | 0~400 | 0~1250 | 0~ 10000 | ||||
| Low resolution(um) | 0.1 | 0.1 | 10 | ||||
| Value error | One point calibration(um) | ±(3%H+1) | ±(3%H+10) | ||||
| Two point calibration(um) | ±[(1~3) %H+0.7] | ±[(1~3)%H+1] | ±[(1~3)%H+10] | ||||
|
Тест условия
|
Minimum radius of curvature(um) | convex | 1 | 1.5 | flat | 10 | |
| The diameter of the smallest area(mm) | 3 | 7 | 7 | 40 | |||
| Critical matrix thickness(mm) | 0.2 | 0.5 | 0.5 | 2 | |||
| Probe model | N1 | CN02 | |||||
| Принцип работы | Eddy current | ||||||
| Measuring range(um) | 0~1250 | 10~200 | |||||
| Low resolution(um) | 0.1 | 1 | |||||
| Value error | One point calibration(um) | ±(3%H+1.5) | ±(3%H+1) | ||||
| Two point calibration(um) | ±[(1~3) %H+1.7] | - | |||||
| тест
условия
|
Minimum radius of curvature(um) | 3 | Only for flat | ||||
| The diameter of the smallest area(mm) | 5 | 7 | |||||