Инфракрасный быстрый калибратор BX-350
- Описание
- Расследование
Описание
Calibrator
BX-350 parameters:
[Введение]
BX-350 Portable Infrared Calibrator (Blackbody Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. В нем есть 2 types of power supply to choose from, one is AC220V and the other is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged
[особенность]
Small and compact design, can calibrate infrared temperature to 350 ℃, large 2.25 дюймы (57мм) black body
Точность: Ambient operating temperature is 5-35 °С (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.5 °С; 50 °С <temperature≤100 ° C (± 1.2℉; 122℉<temperature≤212℉)
± 1.0 ℃; 100 ℃ < temperature≤200 ℃ (± 2.0 ℉; 212 ℉ < temperature≤392 ℉)
± 1.5 ℃; 200 ℃ < temperature≤350 ℃ (± 3.0 ℉; 392 ℉ < temperature≤662 ℉)
Стабильность: Ambient operating temperature is 5-35 ℃ (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa
± 0.1 ℃; 50 ℃ <temperature≤100 ℃ (± 0.2 ℉; 122 ℉ <temperature≤212 ℉)
± 0.2 ℃; 100 ℃ < temperature≤200 ℃ (± 0.4 ℉; 212 ℉ < temperature≤392 ℉)
± 0.3 ℃; 200 ℃ < temperature≤350 ℃ (± 0.6 ℉; 392 ℉ < temperature≤662 ℉)
[Технический индекс]
Диапазон: 50 ° C-350 ° C (122 ° F-662 ° F)
Target emissivity: fixed at 0.95
Разрешение: 0.1 ℃ / 0.1 ℉
Heating time: 30 minutes to the maximum temperature
Cooling time: 40 minutes to 100 °С (122 ° F)
Target diameter: 57мм
Источник питания: 220ВАК (± 10%), 1.25А / 110ВАК (± 10%), 2.5
Размеры: 180 × 114 × 233mm
Масса: 3кг
Calibrator
X-500 parameters:
[Введение]
BX-500 Portable Infrared Calibrator (Black Body Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has two kinds of power supply to choose from, one is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged.
[особенность]
1. Small and compact design,
2. Calibrate infrared high temperature to 550 ℃,
3. Hit a 2.25 дюйм (57мм) black body target.
Точность
Ambient operating temperature: 5-35 °С (41 ~ 95 ° F), относительная влажность: 15 ~ 80%, air pressure: 75kPa ~ 106kPa
± 0.8 ℃; 50 ℃ <temperature≤100 ℃ (± 1.6 ℉; 122 ℉ <temperature≤212 ℉)
± 1.6 °С; 100 °С <temperature≤200 ° C (± 3.2 ° F; 212 ° F <temperature≤392 ° F)
± 2.8 °С; 200 °С <temperature≤500 ° C (± 5.6 ° F; 392 ° F <temperature≤932 ° F)
стабильность
The ambient operating temperature is between 5 и 35 °С (41 к 95 ° F), the relative humidity is 15 к 80%, and the air pressure is 75 kPa to 106 кПа
± 0.1 °С; 50 °С <temperature≤100 ° C (± 0.2 ° F; 122 ° F <temperature≤212 ° F)
± 0.2 °С; 100 °С <temperature≤200 ° C (± 0.4 ° F; 212 ° F <temperature≤392 ° F)
± 0.4 °С; 200 °С <temperature≤500 ° C (± 0.8 ° F; 392 ° F <temperature≤932 ° F)
[Технический индекс]
Диапазон: 50 ° C-500 ° C (122 ° F-932 ° F)
Target emissivity: fixed at 0.95
Разрешение: 0.1 ℃ / 0.1 ℉
Heating time: 40 to maximum temperature
Cooling time: 45 minutes to 100 °С (122 ° F)
Target diameter: 57мм
Источник питания: 220ВАК (± 10%), 1.25А / 110ВАК (± 10%), 2.5
Размеры: 180 × 114 × 233mm
Масса: 3кг
|
BX-350 |
BX-500 |
|
|
Calibration temperature range |
50-350℃ |
50-500℃ |
|
Базовая точность |
±0.5℃(100℃) |
±0.5℃(100℃) |
| ±1.2℃(350℃) | ±1.8℃(500℃) | |
|
Stability rate |
±0,1℃(100℃) | ±0,1℃(100℃) |
| ±0.2℃(350℃) | ±0.3℃(500℃) | |
| heating time | 30 minutes to maximum temperature | 40 minutes to maximum temperature |
| Cooling time | 30 minutes to 100 ℃ | 45 minutes to 100 ℃ |
| Разрешение | 0.1℃ | |
| Target diameter | 57мм (2.25 дюймы) | |
| Target emissivity | Зафиксированный 0.95 | |
| источник питания |
AC 230v (± 10) 1.5А; or AC 110v3A |
|
| размер | 181 * 114 * 233мм | |
| масса | 2682г | |