Блог

МЭК 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (вести, кадмий, mercury, hexvalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) -RoHS test procedure

RoHS compliance testing IEC 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (вести, кадмий, mercury, hexvalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) -RoHS test procedure Procedure for determination of concentrations of the six substances limited to use in electrical and electronic products (вести,...

Читать далее...

The portable X-ray fluorescence spectrometer Compass200 determines tungsten, molybdenum and tin ores

Tungsten, Kun, tin mineral resources are important mineral resources in our country, its minerals are often associated with copper, вести, цинк, bismuth and other heavy metal elements, metallogenic elements tungsten, molybdenum, tin classical analysis methods are mostly single element analysis, and the steps are cumbersome, long process, cost a lot...

Читать далее...

Composition analysis of NdFeB magnetic materials by solution-powder Compass200 XRF Energy dispersive fluorescence spectrometer

Combining the preparation of samples by chemical acid dissolution method and the measurement of samples by X-ray fluorescence (РФА) spectroscopy, a rapid quantitative analysis method for common principal and trace impurity elements of NdFeB alloy was established. A set of reference standard samples was made by our own, which is...

Читать далее...

Determination of platinum content in platinum ruthenium alloy by energy dispersive X-ray fluorescence spectrometer EDX6000 gold detector

EDX-6000 Precious Metal Jewelry detector Energy Dispersion X-ray Fluorescence spectrometer Gold detector Features: Small spot (1мм), accurate fixed point test Vertical light path design, effectively reduce the impact of non-planar samples on test results Accurate, fast and non-destructive> -- Key test, quickly get started No need to repeat calibration every day, improve the detection...

Читать далее...

X-ray fluorescence spectrometer FAQ Series 1

вопрос: What are the six substances restricted by RoHS? А: Hexavalent chromium, кадмий, вести, mercury, polybrominated biphenyls and polybrominated diphenyl ethers. вопрос: What are the maximum content limits for each of the six substances restricted by RoHS? А: The hexavalent is 1000PPM, cadmium is 100PPM, mercury is 1000PPM, lead is 1000PPM, polybrominated biphenyls...

Читать далее...

Analysis method of hazardous substances in RoHS2.0 decree

Restricted substance Raw material Quick scan method Method of accurate laboratory confirmation Refer to Cadmium (Cd) Вести (Pb) plastic rubber Paint Ink X-ray fluorescence analyzer Atomic absorption "AAS" ICP-OES Cadmium (Cd) samples were pre-treated according to EN1122:2001; An alytical method Cd:lSO 3856-4:1984:1SO 11885:1995 Pre-processing of Pb samples is based on EN 13346:2000 or EPA3052:1996; EPA30508 Rew.2:1996 or EN13346:2000; БС; В 1122:2001 (Methods, methods...

Читать далее...