TH2810D Digital Inductance Meter TH2811D
- Descrição
- Investigação
Descrição
Inductance Meter
Características
100Hz,120Hz,1kHz,10kHz 4 typical test frequencies
4.3 inch TFT liquid crystal display, Chinês e Inglês
optional operation interface
6-digit reading resolution
Maximum test speed:12.5EM, support low frequency and high
velocidade:TX4+3ms
10 bins sorting, test sorting is more perfect
100 sets of LCRZ instrument setting files, 10 measurements
Soft power switch
Support 110V/220V two power supply voltages
10-point list sweep, support multi-frequency test sorting
Ultra-low signal source output offset (<100μV), meeting the
needs of large inductor, common mode choke inductor test
Super impact protection
Power on state lock button;
Empty fixture judgment
Data logging function
Screen capture function
Interface function, timing, trigger delay, etc.. are more complete
Inductance Meter
Parâmetro técnico
| Modelo | TH2810B+ |
| Precisão Básica | 0.1% |
| Test Frequency | 100Hz,120Hz,1kHz,10kHz |
| Test Parameters | eu, C, R,Z|, D, P, X, θd, θr, Vm, Im, % |
| V/I Monitor | Sim |
| AC Test Signal Level | 0.1VRMS,0.3VRMS,1VRMS |
| Signal Source Internal Resistance | 10Oh, 100Oh |
| Test Terminal Configuration | 5-terminal |
| Teste de velocidade(ms/time) | Rápido: 19EM; Medium:83EM; Lento: 333msF≤120Hz Fast :4XT+3ms |
| Zero Clearing | Open, Short, Carregar |
| List Sweep | 10-point list sweep; Each scan point can be individually sorted, support multi-frequency combined test sorting; Scanning test for frequency and AC voltage |
| EquivalentCircuit | Series, Paralelo |
| Range Mode | AUTO, HOLD |
| Modo de disparo | interno, Externo, Manual, Bus |
| Average Times | 1-255 |
| Arithmetical Operation | Direct reading, abdômen,% |
| Delay | Trigger delay, step delay: 0—60.000s, 1ms step |
| General Function | Series, parallel equivalent mode, calibração: open circuit, curto circuito, range selection: automatic, manual, trigger mode: INT, MAN,EXT, BUS, keyboard lock function |
| Comparador | 10 bins sorting,BIN1-BIN9,NG,AUX; Bin count function PASS, FALL front panel LED display |
| Nonvolatile Storage | 100 sets of LCRZ instrument setting files, 10 test results |
| External USB Storage | Instrument setting file, CSV data file |
| Modelo | TH2810D | TH2811D |
| Measurement Function | ||
| Test Parameter | L-Q, C-D, R-Q,Z|-P | |
| Precisão Básica | 0.1% | 0.2% |
| Equivalents Circuit | Series, paralelo | |
| Mathematical Functions | Deviation and PercentDeviation | —— |
| Rang Mode | Auto, Segurar | |
| Modo de disparo | interno, Manual andExternal | interno |
| Measurement Speed | Rápido: 12, Med: 5.1, Lento: 2.5 (meas/ sec) | |
| Correction Function | Open/Short multi-frequency Zeroing | |
| Measurement Terminals | Five Terminals | |
| Test Signal | ||
| Test Frequency | 100Hz,120Hz,1kHz,10kHz,Precisão 0.01% | |
| Temperatura de operação & Umidade | 0°C – 40°C, ≤90% UR | |
| Power Requirements | Tensão | 99V – 121V, 198V – 242V |
| Frequência | 47.5Hz – 63Hz | |
| Power Consumption | ≤20 VA | |
| Dimensões (W × H × D.) | 270mmx130mmx300mm | |
| Peso | Aproximadamente. 3.7kg | |