Descrição

NanolinkS900 Zeta Potential Analyzer

Characteristics:

Zeta potential analyzers are typically produced due to ion dissociation on the particle surface, leaving a net charge surrounded by a cloud of counter-ions near the surface. Various types of ions can diffuse in and out through sliding surfaces that allow the Zeta potential to vary depending on the ionic composition in the liquid, such as pH. Ions can also influence the Zeta potential by participating in chemical reactions within the sliding surface.

 

The electrostatic potential 1 of particles suspended in a liquid is very close to the surface position. The Zeta potential (ζ) is caused by particle-to-particle interactions in a colloidal system, so it can be used to predict the stability of particle aggregation in a colloidal system. Figura 1 shows particles suspended in a liquid and the various conceptual regions around them. Zeta potential refers to the potential of a sliding or shearing surface in a liquid. In this plane of slip, as the liquid moves freely outside this boundary, it binds to the particle. The net electric potential away from the particle (in the liquid) is zero.

 

In aqueous media, Zeta potential analyzers are usually produced due to ion dissociation on the particle surface, leaving a net charge surrounded by a cloud of counter-ions near the surface. Various types of ions can diffuse in and out through sliding surfaces that allow the Zeta potential to vary depending on the ionic composition in the liquid, such as pH. Ions can also influence the Zeta potential by participating in chemical reactions within the sliding surface. Sample dilution can significantly change the Zeta potential because ions can adsorb or resolve the particles. Thus, the Zeta potential can be positive or negative, or zero (isoelectric point, IEP), depending on the pH of the liquid (solvent) or the type and concentration of ions.
NanolinkS900 is a new generation of nanoparticle particle size analysis system developed based on many years of scientific research results, which is widely used in the particle characterization of organic and inorganic particles, emulsions, polymers, surfactants, colloids, viral antibodies, protein-like samples. In addition to particle characterization, it can also measure the Zeta potential of colloid.

 

NanolinkS900 Zeta Potential Analyzer

Parâmetro

princípio de medição princípio de medição
faixa de tamanho de partícula 0.3nm-15μm*
grau de precisão Better than ±1% (average particle size, NIST-traceable latex standard)
repetibilidade Better than ±1% (average particle size, NIST-traceable latex standard)
Minimum sample concentration 0.1mg/ml*
Minimum sample size 3μl*
measuring angle Classic 90 graus
Temperature control range 0-90℃ (120℃match)
Precisão do controle de temperatura ±0.1
condensation control Dry gas purge
laser 532nm solid-state laser, maximum power 50mW, laser output automatically adjustable
Laser safety class Aula 1
correlator The minimum sampling time is 25ns and the dynamic range is >1011
detector High sensitivity APD or PMT
configuração do computador Processador Intel i5, 4GB RAM, 250GB hard disk and display, mouse and keyboard
interface de computador USB 2.0 or above
sistema operacional janelas 7 Or above professional version
operating ambient temperature 5-40
Umidade ambiente operacional 10%-85% humidade relativa (sem condensação)
exigência de energia CA 220V, 50/60Hz, Terreno Padrão
peso 25kg
tamanho 578mm x 397mm x 248mm(CxLxA)
Observação: * Depends on sample and pool options