Description

VDT-S10 Cycle Drop Generator

Product Description

 Voltage sags, short interruptions are caused by sudden changes in power grid, power facility failures or loads. In some cases there will be two or more consecutive rollovers or interrupts. The voltage change is caused by a continuous change in the load connected to the grid. If the EUT on the power supply voltage changes cannot respond in a timely manner, it may lead to failure. The voltage drop generator is used to evaluate the performance of electrical and electronic equipment when subjected to voltage sags, short interruptions, and voltage changes. Products fully meet the latest requirements of IEC/ EN 61000-4-11.

VDT-S10 Cycle Drop Generator
Features
  • Fully Compliant with latest Standards IEC/ EN 61000-4-11
  • User friendly 7” Touch Panel Display
  • Support multi-language & facilitate users
  • Built-in environment self-test program
  • Programmable operation
  • Pre-programmed IEC 61000-4-11 test settings
  • RS232 interface, PC control operation & printable test report
  • Comfortable use and convenient operation
VDT-S10 Cycle Drop Generator
Technical data
Model VDT S10

Voltage

1~80V

Voltage variation range

0~120%
Voltage change duration 1~ 9999 half cycle
Switching phase 0~ 359°synchronous, asynchronous, or automatic
Built-in standard test grade 0, 40%, 70%, 80%
Jump time 1μs~ 5μs
Voltage changes in the number of repeat 1~ 9999
Interval cycle of voltage variation 1~ 9999 half cycle
Drop mode Set at random
EUT capacity 1 phase, 10A
Power supply AC220V 50/60Hz
Ambient temperature 15℃~ 35℃