Description

Withstanding Voltage Tester

Features
High power: AC 5kV / 100mA / 500VA output
High security:
High-voltage floating output design, in line with the safety
requirements of EU standards EN50191 (only TH9110)
Electric shock protection function
High resolution: 7 inch 800 × 480 dots, TFT-LCD display
Brand-new operation interface, Chinese and English menu
ARC detection function
Contact check function (OSC)
Breakdown voltage test function
One-key screen capture function
One-key recording function
Rear panel output function to facilitate automated production line testing
Storage: 100 files, up to 50 steps per file

Withstanding Voltage Tester

Application
Winding devices
Transformers, generators/motors and other products needing high
-power withstand voltage test and analysis, such as different types of
motor stator, rotor and other high parasitic capacitance products
Electronic components
Capacitors, coils, cores, choke coils, filters and so on
Electrical products
Household appliances, information products, audio-visual
equipment, electric heating appliances, lighting equipment

Withstanding Voltage Tester

 Technical Parameter

Model TH9110 TH9110A
Withstand Voltage Test
Output Voltage AC 0.05 – 5kV             Load Variance:1%         Accuracy:1%       Resolution: 2V
DC 0.05 – 6kV             Load Variance:1%         Accuracy:1%       Resolution: 2V
Current Test Range AC 0.001mA – 120mA(Voltage≤4kV);0.001mA – 100mA(Voltage>4kV) Accuracy:1%        Resolution:1μA
DC 0.0001mA – 25mA               Accuracy:1%        Resolution:0.1 μA
Output Power 500VA
Insulation Resistance Test
Output Voltage : 0.05 – 5kV       Resolution:2V           Accuracy:1% of set value + 0.1% full scale
Resistance Test Range 1MΩ-50.0GΩ           Resolution:0.1MΩ
Discharge Function Automatic discharge after the end of the test
ARC Detection AC 1mA – 20mA
DC 1mA – 10mA
Contact Check Function OSC open and short:600Hz, 0.1s
Security Features
High Voltage Floating Output Leakage current <3 mA ——
Electric Shock Protection 0.5mA ±0.25mA
Other Protection Start protection, panel operation password protection
Alarm Indication PASS: short tone, green light; FAIL: long tone, red light
Memory groups, 50 steps per group
General Parameters
Voltage Rise Time 0.1s — 999.9s
Test Time Setting(AC/DC) 0.3s — 999s
Voltage Fall Time 0.1s — 999.9s
Waiting Time (IR) 0.2s — 999.9s
Time Accuracy ±(1%+0.1s)