Description

KGZW-110 Energy Logger Data Recorder

Product Introduction
KGZW-110 power quality analyzer is a special portable product for the detection and analysis of power grid operation quality. It can provide harmonic analysis and power quality analysis in power operation, and can conduct long-term data acquisition and monitoring of power grid operation.

 

KGZW-110 Energy Logger Data Recorder

Product Characteristics
1, the instrument uses the touch screen to make the operation more simple and convenient
2, can be measured, and save the data, upload it to the PC for analysis;
3, Chinese menu operation, easy to learn.
4, modular structure, reasonable design, reliable operation.
Product features:
1, voltage/current/frequency measurement function
2, harmonic measurement function
3, power measurement function
4, three-phase unbalance measurement function
5, surge current measurement function
6, fluctuation/flicker measurement function
7, sudden rise/drop measurement function
8. Monitoring and recording function
9, digital oscilloscope function

 

KGZW-110 Energy Logger Data Recorder

Product Parameters
project name

Measurable range accuracy of measurement explain
Voltage/current/frequency Three-phase voltage: 10~700V(true RMS)
Neutral line voltage: 1 ~ 70V(true RMS)
Three-phase current: 0~1000A(true RMS value, optional 1000A current sensor)
Neutral line current: 0~25A(true RMS, optional 25A current sensor)
Frequency: 40~70Hz
Voltage: ±0.5%
Current: ±0.5%
Frequency: ±0.01Hz

The A-phase voltage frequency is used as the measurement frequency

harmonics measurement
Voltage harmonics: total harmonics, 1~50 harmonics
Current harmonics: total harmonics, 1-50 harmonics
Voltage harmonics: total harmonics, 1~50 harmonics
Current harmonics: total harmonics, 1-50 harmonics
power measurement
Active power: 0.05~700KW
Apparent: 0.05~700KVA
Reactive power: 0.05~700KVAR
Power factor: 0.00~1.00
Active power: 0.01~10000kWh
Apparent electrical energy 0.01~10000kVAh
Reactive power 0.01~10000kVARh
Average power factor: 0.00~1.00
Active work: ±2%
Apparent: ±2%
Reactive power: ±2%
Power factor: Reading ±0.005
Active energy: ±2%
Apparent energy: ±2%
Reactive power: ±2%
Average power factor: Reading ±0.005
three-phase imbalance Fundamental voltage: 10~700V(true RMS)
Fundamental current: 0.5~1000A(true RMS)
Fundamental frequency: 40~70Hz
Phase Angle: 0~360
Unbalance degree: 0.0%~100%
Voltage: 0.5%
Current: 0.5%
Frequency: Reading ±0.01Hz
Phase Angle: Reading ±0.3 mm
Voltage unbalance: reading ±0.2
Current imbalance: Reading ±0.2
The A-phase voltage frequency is used as the total measurement frequency
project name Measurable range Measurement accuracy explain
monitoring record Recorded parameters: three-phase voltage, three-phase current, zero-line current, voltage harmonics (total harmonics, 1-25 harmonics), current harmonics (total harmonics, 1-25 harmonics), three-phase unbalance, active power, power factor, fluctuation, flicker
Recording duration = (Maximum number of data that can be recorded by the instrument x storage interval) /60 minutes =18635*3 seconds /3600 seconds =15.5 hours
Storage interval: 3S to 30Mmin
Record duration: 15 hours to 388 days                
Set the collection interval to 3 seconds, can monitor 15.5 hours, set the collection interval to 30 minutes, can monitor 388 days (3 seconds to 30 minutes continuously adjustable)
Sudden rise and sudden fall
Voltage surges, voltage plunges and temporary power outages
A maximum of 40 events can be recorded
Fluctuation
magnitude of a voltage fluctuation:0.1%~10.0%
measuring error:±5%
flickering Short-time flicker
Long time flicker
Short time flicker measurement error :± 5%
Long time flicker measurement error: ± 5%
digital oscilloscope Three phase voltage, three phase current, zero line voltage and zero line current instantaneous waveform Maximum sampling frequency: 200KHz
Minimum sampling frequency: 100Hz
Model 
HDGC3531
display screen Touch screen, color graphics LCD
communication interface
USB
weight
1.0KG
memory
64M bit