Description

KGXZ CVT Test Voltage Booster Device

Product Introduction
During the calibration of capacitive voltage transformer (CVT), the test frequency must be carried out under the condition of 50Hz. At the same time, the site geographical conditions are complex, and the traditional experimental device has been difficult to meet the requirements of field handling and testing. The resonant boost device used for KGXZ CVT inspection is the first adjustable resonant device used for field calibration in China. It has been widely used in the field calibration of capacitive voltage transformers of 500kV and below in China.

 

KGXZ CVT Test Voltage Booster Device

Product Characteristics
1, the output voltage and current waveform is good, the distortion is less than 0.5%;
2, the required power capacity is small, the required power capacity is 1/Q times the test capacity, and the Q value can be 20 ~ 60;
3, there is no need for overvoltage protection, when the test product breakdown, the system is out of tune, the resonant high voltage disappears, the reactor immediately plays a role in limiting the short circuit current, will not aggravate the damage to the test;
4, easy to move, the device is a dry combination series resonant device, composed of excitation transformer and a plurality of resonant reactors, a single component unit small size, light weight, easy to move, suitable for field use;
5, the protection function is perfect, with zero protection (voltage output control knob is not zero, forbid the system to start), overvoltage protection, overcurrent protection, flashover protection and other functions to ensure the reliability of the system.

 

KGXZ CVT Test Voltage Booster Device

Product Parameters
service conditions                                           environment temperature:10℃~+40℃                                                                         
environment temperature:≤90%
working frequency 50HZ
input voltage AC220(single phase)
Output voltage waveform distortion degree excel 0.5%
Rated input capacity 5KVA(2 piece electric reactor)
5KVA(4 piece electric reactor)
10KVA(6-8 piece electric reactor)
Rated input voltage 220V(4 piece electric reactor)
Rated input voltage 22.7A/45.4A
Rated output voltage 76.2KV(2 piece electric reactor)
152.4KV(4 piece electric reactor)
209.6KV(6 piece electric reactor)
303.1KV(8 piece electric reactor)
rated output current 0.5A/1A
Single reactor withstand voltage 40KV/60KV
Capacity of single reactor 20KVA/40KVA/60KVA                                                                        
Capacity of single reactor                                           45kg/60kg

 

KGXZ CVT Test Voltage Booster Device

Major dispositions

product model 35/0.5       66/0.5     110/0.5     110/1     220/0.5     220/1      330/0.5    330/1    500/0.5    550/1      
Capacity of pressure regulating control box 5KVA 5KVA 5KVA 5KVA 6KVA 10KVA 10KVA 15KVA 10KVA 15KVA
rated high voltage(KV) 24.2 45.7 76.2 76.2 152.4 152.4 209.6 228.6 303.1 346.4
Number of reactors 1 1 2 2 4 4 6 4 8 6
Single reactor withstand voltage 40KV 50KV 40KV 40KV 40KV 40KV 60KV 40KV 40KV 60KV
Capacity of single reactor 20KVA 25KVA 20KVA 40KVA 20KVA 40KVA 20KVA 60KVA 20KVA 60KVA

 

KGXZ CVT Test Voltage Booster Device

Trial scope

product model                Typical range of application
KGXZ(C)-35/0.5 All CVTS with a voltage class of 35KV and a capacitance of 0.04UF or less
KGXZ (C)-66/0.5 All CVTS with a voltage class of 66KV and a capacitance of 0.04UF or less
KGXZ (C)-110/0.5 All CVTS with a voltage class of 110KV and a capacitance of 0.02UF or less use two reactors in series                           
KGXZ (C)-110/1 All CVTS with a voltage class of 110KV and a capacity of 0.04UF or less use two reactors in series
KGXZ (C)-220/0.5 All CVTS with a voltage class of 220KV and a capacitance of 0.01UF or less use two reactors in series
KGXZ (C)-220/1 All CVTS with a voltage class of 220KV and a capacitance of 0.02UF or less use two reactors in series
KGXZ (C)-330.0.5 All CVTS with a voltage class of 330KV and a capacity of 0.0075UF or less are connected in series with two reactors
KGXZ (C)-330/1 All CVTS with a voltage class of 330KV and a capacitance of 0.015UF or less use two reactors in series
KGXZ (C)-500/0.5 All CVTS with a voltage class of 500KV and a capacity of 0.005UF or less are connected in series with two reactors
KGXZ (C)-500/1 All CVTS with a voltage class of 500KV and a capacitance of 0.01UF or less are connected in series with two reactors