Ac withstand voltage gas test transformer is the test equipment of electric power equipment testing and preventive test institute. With the rapid development of the electric power industry in our country, the voltage level requirements of the power preventive test transformer are also higher and higher, and the traditional oil immersion test transformer and dry type test transformer no matter in the volume, weight or in performance can not meet the requirements of the field work more and more, with the progress of the electric power research, the application of new materials and new technology, The new medium sulfur hexafluoride gas to the application field of power equipment, sulfur hexafluoride gas has excellent insulation performance and arc extinguision performance and non-flammability, so as a new insulation medium is widely used, SF6 inflatables test transformer is power equipment testing and preventive test laboratory test equipment. Can be used as a non-local discharge test device combination.
pulse test transformer
Product Features
1, pneumatic test transformer is small in size and light in weight (40%-65% lighter than the same grade oil immersion test transformer). 2, clean, no oil, no maintenance.
3, not affected by harsh climate environment, field handling must not be static to do the test.
4, insulation strength is significantly higher than oil immersion test transformer, corona is small.
5, no oil leakage phenomenon and oil pollution, single voltage level up to 300KV.
6, Inflatable test transformer is suitable for field work and frequent moving working conditions.
pulse test transformer
Product name
Inflatable test transformer, power high voltage inflatable test transformer, type inflatable test transformer, cascade inflatable test transformer, inflatable test variable, inflatable test variable, inflatable test variable, AC and DC SF6 gas test transformer, high voltage inflatable transformer, AC inflatable test transformer, DC inflatable test transformer, three-phase experimental transformer, AC and DC test transformer Equipment, pressure test equipment, insulation pressure tester
| Low pressure side | High pressure side | Ratio of measurement | Temperature rise of °C in 60 minutes | Resistance voltage % | No load current% | |||||
| capacity | voltage | current | voltage | current | Quality
|
Dimensions | ||||
| KVA | V | A | KV | mA | KG | L*W*H | ||||
| 3 | 200 | 15 | 50 | 60 | 500 | 50 | 10 | <4 | 27 | 240*300*690 |
| 5 | 200 | 25 | 50 | 100 | 500 | 50 | 10 | <4 | 52 | 250*355*710 |
| 10 | 200 | 50 | 50 | 200 | 500 | 50 | 10 | <4 | 80 | 260*375*750 |
| 15 | 400 | 37.5 | 50 | 300 | 500 | 50 | 8 | <4 | 120 | 270*420*800 |
| 20 | 400 | 50 | 50 | 400 | 500 | 50 | 8 | <4 | 140 | 285*440*820 |
| 30 | 400 | 75 | 50 | 600 | 500 | 50 | 8 | <4 | 155 | 290*386*840 |
| 50 | 400 | 125 | 50 | 1000 | 500 | 50 | 8 | <4 | 184 | 320*416*910 |
| 10 | 200 | 50 | 100 | 100 | 1000 | 50 | 10 | <4 | 135 | 350*475*1300 |
| 10 | 200 | 50 | 120 | 83 | 1000 | 50 | 10 | <4 | 135 | 350*475*1300 |
| 15 | 400 | 37.5 | 100 | 150 | 1000 | 50 | 8 | <4 | 150 | 510*390*1320 |
| 20 | 400 | 50 | 100 | 200 | 1000 | 50 | 8 | <4 | 215 | 540*400*1340 |
| 30 | 400 | 75 | 100 | 300 | 1000 | 50 | 8 | <4 | 250 | 560*410*1360 |
| 50 | 400 | 125 | 100 | 500 | 1000 | 50 | 8 | <4 | 190 | 600*460*1410 |
| 10 | 200 | 50 | 100 | 66.7 | 1500 | 50 | 10 | <4 | 180 | 265*380*1750 |
| 15 | 400 | 37.5 | 150 | 100 | 1500 | 50 | 8 | <4 | 200 | 510*390*1800 |
| 30 | 400 | 50 | 150 | 133.3 | 1500 | 50 | 8 | <4 | 220 | 540*415*1800 |
| 30 | 400 | 75 | 150 | 200 | 1500 | 50 | 8 | <4 | 280 | 560*430*1800 |
| 50 | 400 | 125 | 150 | 333.3 | 1500 | 50 | 8 | <4 | 340 | 640*490*1850 |