Description

Battery Integrated Tester

The common rechargeable batteries include lithium batteries, nickel cadmium batteries, nickel hydrogen batteries, and sealed lead-acid batteries. Among them, lithium battery has the characteristics of large capacity, light weight and high cycle times. It is widely used in mobile phones, PDA, digital cameras, camcorders, notebook computers and other fields.Is currently the most advanced rechargeable battery, referred to here is the finished lithium battery lithium battery pack by lithium batteries (lithium ion batteries or Li polymer batteries) and lithium battery protection board. Nickel cadmium battery is a relatively early application of rechargeable battery. It has the characteristics of low cost, low internal resistance and high current discharge. So far, it has been widely applied in some electric tools and electric cars.

Similar NiMH battery and nickel cadmium battery, but because they do not contain heavy metals, so the environmental pollution is small, at present in some common consumer electronic products have been widely applied in fields of application, has replaced the previous nickel cadmium batteries. Small sealed lead-acid battery, also known as maintenance free lead-acid electric he, at present mature technology, mainly used in fixed backup power applications, such as uninterruptible power supply, emergency lighting and so on.

Technical parameter 

Model JK5530 JK5530B
Measuring range Range of battery voltage measurement 0-36V,Minimum resolution 10mV,accuracy:±30mV 0-60V,Minimum resolution 10mV,accuracy:±5mV
Range of internal resistance measurement 0-999mΩ,Minimum resolution 1mΩ 0-1999mΩ,Minimum resolution 1mΩ
Capacity measurement range 0-10000mAH,Minimum resolution 1mAH
Measurement accuracy Accuracy of voltage measurement ±(result *0.1%+3mV)(voltage0~36V)

±(result*0.1%+30mV)(voltage37~62V)

Accuracy of current measurement ±(result *0.2%+30mA)(current 0~10A)

±(result *0.5%+30mA)(current 11~30A)

Accuracy of internal resistance measurement ±(result *1%+1mΩ)
Accuracy of battery capacity measurement 10AH :±5% 100AH :±5%
Test speed Static test (test all functions) 1.1-2 seconds
Capacity test (1C current charge and discharge) 3-4 hours
Internal numerical control voltage source index Maximum output voltage 16V 62V
Maximum output current 5A
Maximum output power 80W 200W
Ripple voltage <20mV <100mV
Load adjustment rate <10%
response time 1S
Internal numerical control electronic load index Ceiling voltage 60V 80V
Maximum discharge current 10A (continuity),15A(10 second) 30A(continuity) 40A(2 second),60A( Need to be customized)
Limit power 50W(continuity),80W(10 second) 200W (continuity)
supply voltage 220V±10%50Hz
U disk storage   no yes
communication interface   no yes(with Host computer software)
Accessories   Kelvin clip test line, test probe
Size and weight   Upper frame size (mm):215(w)*88(H)*375(D)

Shape size (mm):235(w)*105(H) *430(D), about 3.6kg