Description

Ventilation Aging Chamber

Test standard:

In accordance with the standard GB/ t3512-2014 /ISO 188 2011 “vulcanized rubber or thermoplastic rubber/hot air accelerated aging and heat resistance test” turbulence design.

 Ventilation Aging Chamber

Use

The hot air aging test box is suitable for the heat resistance test of electrical insulation materials, the air exchange aging test of electronic spare parts, plasticized products, etc.The adaptability of the sample to storage and use in high temperature environment was evaluated and judged. The performance of the sample after aging in air under simulated high temperature and atmospheric pressure was measured and compared with the performance of the non-aging sample.

Ventilation Aging Chamber

Enclosure structure

  1. Internal size: 600(width)×600(depth)×650(height)mm;
  2. External dimension: 1300(width)×850(depth)×1700(height)mm, subject to the actual object;
  3. Operation panel: the control panel is located on the right side of the machine (as shown in the figure);
  4. Opening mode: single door is opened from right to left;
  5. Observation window: toughened glass window on the door, size W250*H350mm;
  6. Inner material: 304# stainless steel sand board: thick 1.2mm;
  7. External material: cold-rolled steel plate, 1.0mm thick powder baking paint treatment;(beige)
  8. Product materials: two built-in turntables with a diameter of 300mm;
  9. One set of speed-regulating motors with adjustable speed of 3-20 RPM;
  10. Thermal insulation material: high temperature resistant fiber rock wool, good thermal insulation effect;

11, the door sealing material is: high temperature resistant silicone strip;

  1. The machine is equipped with movable casters and fixed feet, which can be pushed and fixed at any time.

Ventilation Aging Chamber

Temperature control system

  1. Temperature control is PID digital display instrument (Taiwan taisong instrument GB705), single point temperature control, automatic calculation, simultaneous display of PV/SV, button setting;
  2. Timing function: from 1 to 9999 (hour, minute and second can be set), the temperature reaches the timer, when the time arrives, the heating and power supply will stop, and the alarm will be given;
  3. Temperature line (K) type;
  4. The output is 3-32v;
  5. The current controller is: SSR solid state relay;
  6. Heating material: stainless steel high-temperature heating tube;
  7. Temperature range: adjustable from normal temperature +15 to 300℃;
  8. Heating rate: about 18 minutes at 100℃;
  9. Control accuracy: ±0.5℃;
  10. Display accuracy: 0.1℃;
  11. Temperature deviation: RT+15 ~ 200℃±2.0℃, 201 ~ 300℃±3.0℃ (no-load test)Ventilation Aging Chamber Ventilation Aging Chamber