LV/RV/HA/HB/-SSR Rotary Brinell Viscometer
- Opis
- Zapytanie
Opis
LV/RV/HA/HB/-SSR Rotary Brinell Viscometer
Wstęp
LV-SSR Brinell Viscometer adopts coaxial cylinder structure, using small sample adapter, the sample quantity required for each measurement is very small, only 7ml-13ml (wirnik 0 is 21ml), optional constant temperature water jacket with cycle, with constant temperature tank to control the sample under test. The operation is very convenient and the measurement is accurate. very suitable for precious, rare sample measurement.
In the operation of the instrument, this series of instruments has the function of 100% full range value of measured value, range overflow alarm display, automatic scanning function, relying on these, users can intuitively, quickly and accurately select the appropriate available rotor and speed combination, and can save the test conditions determined to facilitate the rapid transfer and use in the future production and testing process.
This series of instruments are widely used in solvent-based adhesives, lateks, biochemical products, malatura, coatings, kosmetyki, atrament, miazga, żywność, starch and other industries.
LV/RV/HA/HB/-SSR Rotary Brinell Viscometer
characteristic:
- Timing measurement function
- Coaxial cylinder structure
- Using a spindle rotor, the sample size required for testing is very small
- Two RS232 interfaces with direct connection to micro printer and computer
LV/RV/HA/HB/-SSR Rotary Brinell Viscometer
Parametry
| Model | LV-SSR |
| tryb wyświetlania | wyświetlacz cyfrowy |
| prędkość(obr./min) | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
| wirnik | 18#,25#,31#,34# (standard configuration) |
| skala | 3-1.6M (mPa﹒s) |
| Rozmiar próbki | 18# wirnik:3 –10K; 7ml
25# wirnik:480 –1.6M; 9ml 31# wirnik:30 –100K; 10.5ml 34# wirnik:60 –200K; 11ml |
| błąd pomiaru | ±3% (Ciecz Newtona) |
| powtarzający się błąd | ±1.5% (Ciecz Newtona) |
| output interface | Two RS232 interfaces to connect printer and computer |
| Temperature Probe Interface | standardowa konfiguracja |
| Wymiar konspektu | 300 × 300 × 450(mm) |
LV/RV/HA/HB/-SSR Rotary Brinell Viscometer
Szczegółowe parametry techniczne
| Model | RV-SSR | Ha-SSR | HB-SSR |
| tryb wyświetlania | wyświetlacz cyfrowy | ||
| prędkość(obr./min) | 0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
||
| wirnik | 21#、27#、28#、29# (standardowa konfiguracja) | ||
| skala | 50 – 2M
21# wirnik:50-100K 27# wirnik:250-500K 28# wirnik:500-1M 29# wirnik:1K-2M |
100 – 4M
21# roto:100-200K 27# roto:500-1M 28# roto:1K-2M 29# roto:2K-4M |
400 – 16M
21# roto:400-800K 27# roto:2K-4M 28# roto:4K-8M 29# roto:8K-16M |
| Rozmiar próbki | 21# roto: 7.8ml
27# roto: 11.3ml 28# roto: 12.6ml 29# roto: 11.5ml |
||
| błąd pomiaru | ±3% (Ciecz Newtona) | ||
| powtarzający się błąd | ±1.5% (Ciecz Newtona) | ||
| output interface | Two RS232 interfaces to connect printer and computer | ||
| Temperature Probe Interface | standardowa konfiguracja | ||
| Wymiar konspektu | 300 × 300 × 450(mm) | ||