KDZD Shielding efficiency tester
- Beschrijving
- Navraag
Beschrijving
Shielding efficiency tester
The test device is composed of three parts: power frequency voltage generator, voltage meter, test electrode combination (brass pressurized electrode; Rubber sheet; Brass receiving electrode; Insulation board; Test fixed disk).
Producteigenschappen
It can test high-voltage shielding suit, electromagnetic shielding suit, equipotential operation shielding suit and 500kv shielding suit
The parts tested include the entire jacket, pants, socks, gloves, and shoes The safety of the suit in terms of resistance and efficiency is accurately measured To ensure the safety of employees in the operation, the whole test device is lightweight and convenient, easy to store and carry.
The layout is reasonable and the appearance is beautiful Easy to operate, with accurate and reliable, easy maintenance and other advantages. Power frequency voltage generator adopts micro-processing control technology, eenvoudige bediening, betrouwbare prestaties, test current and time continuous setting.
| Output voltage range: | AC 0-5000V |
| Voltage resolution | 10V |
| Voltage accuracy | 5% |
| Maximum output current | 20mA |
| Upper current setting | 0.5mA to 20mA |
| Current accuracy | Voltage meter ±5% |
| Transformer capacity | 500VA |
| Maximum output power | 100VA |
| Measurement time setting | 1s-99s |
| Weergavemodus | LED digital display |
| Power requirements | 198V-242V AC, 47.5HZ-55HZ |
| Dimensies | 320×180×250(mm) |
| Gewicht | About 10kg |
Voltage meter
| Basic functional | Bereik |
| Dc voltage | range 200mV/2V/20V/200V/1000V; Basisnauwkeurigheid: ±(0.015%+3) |
| Ac voltage | range 2V/20V/200V/750V; Basisnauwkeurigheid: ±(0.2%+100) |
| Dc current | range 2mA/200mA/10A; Basisnauwkeurigheid: ±(0.05%+10) |
| Ac current | range 2mA/200mA/10A; Basisnauwkeurigheid: ±(0.3%+100) |
| Weerstand | Measuring range 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ; Basisnauwkeurigheid: ±(0.02%+6) |
| Capaciteit | range of nf / 600 nf / 6 uf / 60 uf / 600 uf/mf. Basisnauwkeurigheid: ±(2% +5) |
| Frequentie | range 10Hz ~ 60MHz; Basisnauwkeurigheid: ±(0.1%+3) |
| Stroomvoorziening | AC 220V/50Hz |
| LCD size | 108× 34.5mm |
| Gewicht | Ongeveer. 1500 G (zonder accessoires) |
| Maat | 240*105*70mm |
Test electrode:
| Receiving electrode (Φ110mm×74mm) | 1 |
| Pressure electrode (Φ300mm×2mm brass plate) | 1 piece |
| Synthetic rubber plate Φ400 mm | 1 piece |
| Insulated Plexiglass box 500 mm x 450mm | 1 piece |