Beschrijving

Earth insulation tester

This instrument has LCD large screen grey backlight display, data storage, data reference, alarm, automatic shutdown and other functions. Tegelijkertijd, it also has the function of measuring DC voltage and AC voltage absorption ratio and polarization index. The machine is beautiful and high-grade, wijde selectie, high resolution, convenient operation, easy to carry, accurate, reliable, stable performance, strong anti-interference ability.

And with shock-proof, stofdicht, moisture-proof structure, adapt to the harsh working environment, is telecommunications, electric power, meteorology, computer room, oil field, mechanical and electrical installation and maintenance and the use of electricity as an industrial power or energy industry commonly used instruments. It is suitable for measuring the resistance value of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment.

Earth insulation tester

Functie Isolatieweerstandstest, voltage test
Reference condition 23℃±5℃, less than 75%rh
Nominale spanning (V) 250;500;1000;2500;5000 accuracy ±3%rdg±5dgt
Measuring voltage (V) Rated voltage×(1±10%)
Insulation resistance range (GΩ) 0.01MΩ~200GΩ accuracy ±3%rdg±5dgt
Insulation resistance resolution 0.01MΩ
Dc voltage range 0~1000V
Dc voltage resolution 0.1V
Ac voltage range 0~750V
Ac voltage resolution 0.1V
Output short-circuit current ≥1mA(2500V)
Absorption ratio and polarization index measurement There are
Power source 1.5V (LR14) alkaline battery 6 STUKS
backlight Controllable grey screen backlight, suitable for use in dim places
Weergavemodus 4 digit large LCD display, grey screen backlight
LCD display size 108mm×65mm
Meter size 240mm (L)×188mm (W)×85mm (H)
Test line The high pressure rod is 1 meter red, the high pressure test line is 1 meter black, and the green line is 1 meter
Data opslag 500 group, flashing the “FULL” symbol indicates that the storage is full
Data lookup Data lookup function: de “READ” symbol is displayed
Overflow display Overrange overflow function: “OL” symbol display
Alarm function When the measured value exceeds the alarm setting value, an alarm prompt is issued
Power dissipation Standby: 40mAMax(backlight off)
Turn on backlight: 43mAMax
Measurement: 80mAMax(backlight off)
Quality 1230G(battery included)
Battery voltage The battery voltage is insufficient, and the “2671 meter head” indicator is displayed
Automatic shutdown Instrument no operation 15 minutes off
Isolatieweerstand ≥50MΩ (1000V)
Withstand voltage AC3kV 50Hz 1min
Operating temperature and humidity -10℃~+50℃<85%RH
Storage temperature and humidity -15℃~+55℃<90%RH
Fit for safety IEC61010-1、IEC1010-2-31、IEC61557-1,5、IEC60529(IP54)、pollution, enz 2、CAT Ⅲ 300V

Earth insulation tester Earth insulation tester Earth insulation tester