GA-450A Vertical Resistivity Tester
- Beschrijving
- Navraag
Beschrijving
GA-450A Vertical Resistivity Tester
Invoering
The GA-450A Vertical resistivity tester is used to measure the vertical resistivity and plane resistance of fuel cell carbon paper, bipolar plates or other materials.
Meet the standard:
GB/T20042.7 – Proton exchange membrane fuel cells – Deel 7: Test method for characteristics of carbon paper
GB/T20042.6 Proton exchange membrane fuel cells – Deel 6: Bipolar plate characteristic test method
NBT 42082-2016 all-vanadium flow battery electrode test method
NB_T42007-2013 Test method for bipolar plates for all-vanadium flow batteries
T/CEEIA 577-2022 Electrode materials for iron-chromium flow batteries – Technical requirements and test methods
Meetbereik: (50 ~ 10000)N, (0.05~4MPa), 1mΩ-20kΩ
Pressure resolution: 0.1N
Pressure error: < Plus of minus 0.5%
Pressure Sensor: HBM (Duitsland)
Resistance resolution: 1μΩ, 0.001mΩ
Resistance accuracy: 0.1%
Upper and lower platen parallelism: < De 0.025 mm
Maximum distance between upper and lower pressure plates: 50mm
Upper clamping plate: Area 25cm² round, Φ80 mm(area 50.3cm²) (optioneel)
Bottom plate: Area 25cm² round, Φ80 mm(area 50.3cm²) (optioneel)
Dimensies: 330×350×510mm
Mass: 57kg
Stroomvoorziening: AC110-240V, 50Hz
Connect to computer (standard) : Equipped with computer software, RS232, USB-interface, Bluetooth wireless connection
Man-machine interface: touch screen display in Chinese and English
Producteigenschappen:
◆ Germany HBM high precision force sensor, factory accuracy control at < 0.5%, better than the ISO standard of ±1%.
◆ Automatic test, can be connected to the computer to synchronize the data to the computer software, automatically generate reports and graphs.
◆ Precision ball screw drive, aluminum alloy panel, high quality copper gold-plated upper and lower pressure plate and reasonable design, ensure the instrument durable. Our professional design and programming team can also upgrade the instrument.
◆ Touch screen Chinese display, friendly man-machine interface operation. Complete the test automatically, with the test data statistical processing function, micro printer output, can also be connected to the computer operation. When connected to the computer, in addition to automatically storing the results, the pressure-resistance curve can be displayed and saved.
◆ High performance stepper motor and Silicon Labs high performance chip control ensure accurate transmission, fast and efficient testing.
◆ The calibration procedure is specially set inside the instrument, which is convenient for the measurement and calibration department (third party) to calibrate the instrument. When calibrating, enter the calibration test program, place the standard sensor between the upper and lower pressure plates, and the indication error can be easily calibrated.