Penerangan

pulse test transformer
pengenalan produk
Ac withstand voltage gas test transformer is the test equipment of electric power equipment testing and preventive test institute. With the rapid development of the electric power industry in our country, the voltage level requirements of the power preventive test transformer are also higher and higher, and the traditional oil immersion test transformer and dry type test transformer no matter in the volume, weight or in performance can not meet the requirements of the field work more and more, with the progress of the electric power research, the application of new materials and new technology, The new medium sulfur hexafluoride gas to the application field of power equipment, sulfur hexafluoride gas has excellent insulation performance and arc extinguision performance and non-flammability, so as a new insulation medium is widely used, SF6 inflatables test transformer is power equipment testing and preventive test laboratory test equipment. Can be used as a non-local discharge test device combination.
pulse test transformer
Product Features
1, pneumatic test transformer is small in size and light in weight (40%-65% lighter than the same grade oil immersion test transformer). 2, clean, no oil, no maintenance.
3, not affected by harsh climate environment, field handling must not be static to do the test.
4, insulation strength is significantly higher than oil immersion test transformer, corona is small.
5, no oil leakage phenomenon and oil pollution, single voltage level up to 300KV.
6, Inflatable test transformer is suitable for field work and frequent moving working conditions.
pulse test transformer
Nama produk
Inflatable test transformer, power high voltage inflatable test transformer, type inflatable test transformer, cascade inflatable test transformer, inflatable test variable, inflatable test variable, inflatable test variable, AC and DC SF6 gas test transformer, high voltage inflatable transformer, AC inflatable test transformer, DC inflatable test transformer, three-phase experimental transformer, AC and DC test transformer Equipment, pressure test equipment, insulation pressure tester
  Low pressure side High pressure side Ratio of measurement Temperature rise of °C in 60 minit Resistance voltage % No load current%    
capacity voltan semasa voltan semasa Kualiti

 

Dimensi
KVA V A Kv mA KG L*W*H
3 200 15 50 60 500 50 10 <4 27 240*300*690
5 200 25 50 100 500 50 10 <4 52 250*355*710
10 200 50 50 200 500 50 10 <4 80 260*375*750
15 400 37.5 50 300 500 50 8 <4 120 270*420*800
20 400 50 50 400 500 50 8 <4 140 285*440*820
30 400 75 50 600 500 50 8 <4 155 290*386*840
50 400 125 50 1000 500 50 8 <4 184 320*416*910
10 200 50 100 100 1000 50 10 <4 135 350*475*1300
10 200 50 120 83 1000 50 10 <4 135 350*475*1300
15 400 37.5 100 150 1000 50 8 <4 150 510*390*1320
20 400 50 100 200 1000 50 8 <4 215 540*400*1340
30 400 75 100 300 1000 50 8 <4 250 560*410*1360
50 400 125 100 500 1000 50 8 <4 190 600*460*1410
10 200 50 100 66.7 1500 50 10 <4 180 265*380*1750
15 400 37.5 150 100 1500 50 8 <4 200 510*390*1800
30 400 50 150 133.3 1500 50 8 <4 220 540*415*1800
30 400 75 150 200 1500 50 8 <4 280 560*430*1800
50 400 125 150 333.3 1500 50 8 <4 340 640*490*1850