- Penerangan
- Siasatan
Penerangan
Elcometer
ISO8503 Elcometer (UK) Roughness comparison plate Application: for the assessment of the surface of the shot after sandblasting. Type G is used for the surface after fine abrasive blasting and type S is used for the surface after hard abrasive shot blasting.
ISO8503 Elcometer Roughness Comparison Plate quality: specific low carbon steel with high purity nickel plating as raw material.
ISO8503 British Elcometer standard for roughness comparison plates: Metric units manufactured according to IS08503 standard.
ISO8503 British Elcometer roughness comparison plate classification: divided into sandblasting type (Sa2.5 standard 25, 60, 100, 150satu) and shot blasting type (Sa3 standard 25, 40, 70, 100um two kinds, each is divided into four areas, fine, general, rough three files, Used to meet Sa2.5 and Sa3 standards for sandblasting, shot blasting and surface cleaning.
Elcometer
Instructions for use
(1) Remove all dust and debris from the measured surface.
(2) Select the appropriate sandblasting type or shot blasting surface roughness comparator and correspond it to the test surface. In turn, the test surface is directly compared with the four parts of the comparison board or the test surface is simultaneously observed with a part of the comparison board using a magnifying lens not exceeding 7x. Evaluate the roughness of the comparator closest to the test surface, and then determine its grade. Fine grade surface symbol station comparator 0415032
Part I and Part II below (excluding Part II) general grade surface conformance comparator
Rough grade surfaces below Part II and Part III (excluding Part III) conform to the comparator
Part III and Part IV below (excluding Part IV)
(3) Record the grade of all test surfaces. If any rough surface is considered to be lower than the lower limit of the fine grade, this grade is recorded as a finer grade. If any section is considered to be higher than the upper limit of the rough grade, record the grade as a rougher grade,
(4) or a wooden pointed pen held by the thumb and forefinger is moved over several parts of the test surface and the comparison board to estimate the closest test surface grade.
(5) When the surface is re-shot, the first rough surface may be better than the second rough surface. This second surface is generally evaluated by the use of abrasive and re-blasting operations.
Elcometer
| UK Elgo surface roughness comparison sample E125 | |
| · Suitable for sandblasting and shot blasting | |
| · Metric units | |
| · Comply with ISO8503 standard | |
| Model number | E125-1 |
| Suitable for sandblasting | |
| Grade | 25/60/100/150μm |
| Model | E125-2 |
| Suitable for shot blasting | |
| Grade | 25/40/70/100μm |