ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

A Prakata
ISO (Pertubuhan Antarabangsa untuk Standardisasi) adalah perikatan global badan standard kebangsaan (Badan ahli ISO). Pembangunan piawaian antarabangsa biasanya dijalankan melalui jawatankuasa teknikal ISO. Setiap institusi ahli yang berminat dalam subjek yang mana jawatankuasa teknikal telah ditubuhkan mempunyai hak untuk diwakili dalam jawatankuasa. Pertubuhan Antarabangsa Kerajaan dan Bukan Kerajaan yang Liaisasikan dengan Pertubuhan Standardisasi juga terlibat dalam kerja ini. ISO bekerjasama rapat dengan Suruhanjaya Elektroteknikal Antarabangsa (IEC) mengenai semua perkara standardisasi elektrik.

Prosedur yang digunakan untuk membangunkan dokumen ini serta yang digunakan untuk penyelenggaraan selanjutnya diterangkan sebahagiannya 1 Arahan ISO/IEC. khususnya, perhatian harus diberikan kepada kriteria kelulusan berbeza yang diperlukan untuk pelbagai jenis dokumen ISO. Dokumen ini telah digubal mengikut peraturan editorial Bahagian 2 Arahan ISO/IEC (lihat iso.org/directives).

Sila ambil perhatian bahawa kandungan tertentu dokumen ini mungkin tertakluk kepada hak paten. ISO tidak bertanggungjawab untuk mengenal pasti mana-mana atau semua hak paten tersebut. Butiran mengenai hak paten yang dikenal pasti semasa pembangunan dokumen itu akan berada dalam pengenalan dan/atau dalam senarai ISO tuntutan paten yang diterima (lihat iso.org/patents).

ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

Sebarang nama perdagangan yang digunakan dalam dokumen ini disediakan sebagai maklumat untuk kemudahan pengguna dan tidak menjadi pengesahan.

Voluntary, related standards and conformity assessment related ISO specific and express the meaning of terminology as well as in relevant ISO technical barriers to trade (TBT) mematuhi prinsip organisasi perdagangan dunia (WTO) maklumat, please see the following URL:iso.org/iso/foreword.html.

This document has been prepared by Technical Committee ISO/TC 107, Metallic and other Inorganic Coatings, Subcommittee SC 8, Chemically Transformed Coatings.

The third edition to cancel and replace the technically revised second edition (ISO 9717:2010). The following changes were made:

– scope has clearly;

— Normative references have been updated;

– Terms and definitions have been replaced by references to ISO 2080;

– Article 4 has been amended;

– The terms in clause 5 have been amended;

– The requirements of phosphate layer have been modified;

– The statement on corrosion resistance has been moved to the new Annex A;

– Annex B on salt spray tests has been amended;

— Annex C on properties of phosphate layers has been revised.

ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

pengenalan
Phosphate conversion coatings are applied to ferrous metals, aluminum, zinc and their alloys (including galvanized and zinc-alloyed steel, cadmium and their alloys) as end faces or as interlayers for other coatings. They are designed to

— Imparts corrosion resistance,

– Improves adhesion to paints and other organic finishes,

– promote cold forming operation, such as drawing, tubing, and extrusion, as well

– Modification of surface friction properties to facilitate sliding.

Phosphate conversion coating is produced by solution treatment, its main composition is proper orthophosphoric acid dihydrogen salt. These coatings are mainly applied to ferrous materials and zinc, and the coating quality and apparent density per unit area vary depending on

– component of building materials and surface condition,

– prior to mechanical and chemical processing of parts, as well

– phosphating treatment conditions.

More or less all phosphate conversion coating is porous, but can be by subsequent sealant for which the material sealing process.

ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

Warning requires the use of the file if you don’t take appropriate safety measures may be harmful to the health of the material and/or procedures. This document does not address any health hazards, safety or environmental issues associated with its use. Producers and buyers of this document and/or the user has the responsibility to establish appropriate health, safety and environmental acceptable practices, and to take appropriate action.

1 Skop
This document sets out the process for confirming requirements for phosphate coatings, which are commonly used for ferrous materials, zink, cadmium and their alloys (see Annex B).

2 Rujukan normatif

Dokumen berikut dirujuk secara normatif secara keseluruhan atau sebahagian dalam dokumen ini dan diperlukan untuk permohonan mereka. Untuk rujukan bertarikh, hanya versi yang dipetik digunakan. Untuk rujukan tidak bertarikh, versi baru rujukannya (termasuk sebarang semakan) berlaku.

ISO 2080, Metals and other inorganic coatings — Surface treatments, metals and other inorganic coatings — Vocabulary

ISO 3892, conversion coatings on metallic materials-determination of coating mass per unit area-gravimetric method

ISO 4519, electroplating metal coating and related facing – according to the property inspection sampling procedure

ISO 9227, artificial atmospheric corrosion test, salt fog test

ISO 9717-2017 Phosphate conversion films for metals – Method for determining requirements

3 Terma dan definisi
For the purpose of this document, given in the ISO 2080 terms and definitions apply.

ISO dan IEC mengekalkan pangkalan data terminologi untuk penyeragaman di alamat berikut:

– IEC Electronic Encyclopedia: boleh didapati di electropedia.org/

– Platform pelayaran dalam talian ISO: available at iso.org/obp

Hanya komponen maklumat standard tersedia secara umum. Untuk melihat kandungan penuh, anda perlu membeli piawaian melalui saluran rasmi.