설명

GA-9001-A 디지털 산소 지수 테스터

esign standard:

GB/T 2406.2-2009 GB/T 2406.1-2008,ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996 NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144-1992 ISO 15705-2002 ISO 4589-2-1996

 

GA-9001-A 디지털 산소 지수 테스터

사용

The machine adopts imported SMC pneumatic components and steel frame structure to comprehensively test products with a certain speed and counting stroke, so as to assess product quality problems.

 

GA-9001-A 디지털 산소 지수 테스터

기술 사양

테스트 스테이션 2group or 2 층
Test stroke 0-500mm
테스트 속도 5-10회/분
시간제 노동자 0-999999999 Power off memory protection function, set the number of shutdown function
Action principle Horizontal drawer movement
AC220V 50HZ
기압 6킬로그램
아웃 사이즈 1200*500*700mm
무게 60킬로그램

GA-9001-A 디지털 산소 지수 테스터

에스신청 대처:

It is suitable for the determination of the combustion performance of plastics, 고무, 섬유, foam plastics, film and textile materials

GA-9001-A 디지털 산소 지수 테스터

주요 기술 매개변수

  1. Using imported oxygen sensor, digital display oxygen concentration without calculation, more accurate and more accurate, range 0-100%
  2. The built-in temperature controller to control the temperature, the control range: 23 ℃ ±2 ℃
  3. Digital resolution: 0.1%
  4. 측정 정확도: 0.4 grade
  5. Flow regulation range: 0-10l /min (60-600l /h)
  6. Response time: < 5에스
  7. High temperature resistant quartz glass tube, inner diameter 75 ㎜ height 480 mm or more
  8. Gas flow rate in combustion cylinder: 40mm ±2mm/s
  9. Pressure gauge accuracy 2.5, 해결: 0.01MPA
  10. The flowmeter: 1-15 l/min (60-900 l/H) is adjustable, test environment: the environment temperature: room temperature ~ 40 ℃;, 상대습도: 70%;
  11. Input pressure: 0.2-0.3MPA
  12. Working pressure: nitrogen 0.1-0.15mpa oxygen 0.1-0.15mpa oxygen/nitrogen mixed gas inlet: including pressure regulator valve, flow control valve, gas filter and mixing chamber.
  13. The sample holder can be used for soft and hard plastics, 직물, fire doors, 등
  14. Propane (부탄) ignition system, flame length 5mm-60mm can be adjusted freely
  15. Gas: nitrogen and oxygen for industrial use with purity of > 99%;(user supplied).
  16. Power requirements: AC220 (±10%) V, 50HZ
  17. Maximum working power: 50여
  18. Igniter: made of a metal, end diameter Φ 2 ±1 mm nozzle, can ignite sample in combustion tube, the flame length: 16 ±4 mm, the size is adjustable
  19. Self-supporting material sample holder: it can be fixed in the position of the axis of combustion cylinder and can hold the sample vertically
  20. Non-self-supporting material sample holder: two vertical edges of the sample can be fixed on the frame at the same time (optional for non-self-supporting materials such as textiles and films).