블로그

Composition analysis of NdFeB magnetic materials by solution-powder Compass200 XRF Energy dispersive fluorescence spectrometer

Combining the preparation of samples by chemical acid dissolution method and the measurement of samples by X-ray fluorescence (XRF) spectroscopy, a rapid quantitative analysis method for common principal and trace impurity elements of NdFeB alloy was established. A set of reference standard samples was made by our own, which is...

더 읽어보세요...

Determination of platinum content in platinum ruthenium alloy by energy dispersive X-ray fluorescence spectrometer EDX6000 gold detector

EDX-6000 Precious Metal Jewelry detector Energy Dispersion X-ray Fluorescence spectrometer Gold detector Features: Small spot (1mm), accurate fixed point test Vertical light path design, effectively reduce the impact of non-planar samples on test results Accurate, fast and non-destructive> -- Key test, quickly get started No need to repeat calibration every day, improve the detection...

더 읽어보세요...

X-ray fluorescence spectrometer FAQ Series 1

큐: What are the six substances restricted by RoHS? ㅏ: Hexavalent chromium, cadmium, lead, mercury, polybrominated biphenyls and polybrominated diphenyl ethers. 큐: What are the maximum content limits for each of the six substances restricted by RoHS? ㅏ: The hexavalent is 1000PPM, cadmium is 100PPM, mercury is 1000PPM, lead is 1000PPM, polybrominated biphenyls...

더 읽어보세요...

Analysis method of hazardous substances in RoHS2.0 decree

Restricted substance Raw material Quick scan method Method of accurate laboratory confirmation Refer to Cadmium (CD) Lead (납) plastic rubber Paint Ink X-ray fluorescence analyzer Atomic absorption "AAS" ICP-OES Cadmium (CD) samples were pre-treated according to EN1122:2001; An alytical method Cd:lSO 3856-4:1984:1SO 11885:1995 Pre-processing of Pb samples is based on EN 13346:2000 or EPA3052:1996; EPA30508 Rew.2:1996 or EN13346:2000; BS; 안에 1122:2001 (Methods, methods...

더 읽어보세요...

결정 37 major and minor trace elements in ancient ceramic embryo glaze by energy dispersive X-ray fluorescence spectrometry EDX9000B

  결정 37 major and minor trace elements in ancient ceramic embryo glaze by energy dispersive X-ray fluorescence spectrometry EDX9000B The energy dispersive X-ray fluorescence spectrometer EDX9000B was used to prepare samples of ancient ceramic embryo glaze Na2O,MgO,AI2O3,SiO2,P2O5,K2O,CaO,Sc,TiO2,V205,Cr203,MnO,Fe203,CoO,NiO,CuO,ZnO,가,As,Br,Rb,Sr,와이,Zr,NB,Sn,Sb,Cs,BaO,La,Ce, Nd,Sm,HF,PbO,Bi and Th and other 37 major and minor trace components were determined, using...

더 읽어보세요...