Descrizione

Transformer Test System

All prices are for manual type, if need pneumatic type, need to contact us to add extra costs.
LCR meter function is optional for all of our transformer testers, if need to add LCR meter function, please contact us before place order, Altrimenti, we will ship the devices with standard configuration.

Transformer Test System

Caratteristiche
7-inch TFT LCD display with a resolution of 800×RGB×480
Frequency up to 1MHz, risoluzione: 0.5mHz
Signal level: 5mV-2Vrms, opzionale (2Vrms-10Vrms)
Built-in 0-100mA/0-10V bias power supply, optional 1A/2A bias current source
Fino a 75 volte / sec test speed
Diode forward and reverse characteristic detection
Improved high turns ratio and weakly coupled transformer test capability
Improved DCR testing capabilities
Single screen can accommodate all scan test results
Time stamping system: memory file setting, calibration deviation and deduction time
Sort the selected scanning parameters
Self-test scanning fixture relays
Flexible deviation deduction method
Multiple handling ways for FAIL cases
Single parameter test cycle to test independent windings
Increased security: administrator and operator passwords
Built-in statistical analysis capabilities: Cpk, Cp, Ck, eccetera.
Bar-code reading function can be used to select a setting file or to manage the type of test products
Optional PC-level instrument test setup file programming capability
Online upgrade mode: USBHOST or RS232
Support multiple instrument networking through LAN interface
Backward compatible with TH2818X/TH2819X parameter setting file
Magazzinaggio: Internal: 100 groups of settings file to save
U disk: 500 groups of configuration files, CSV format test data, GIF format images

Transformer Test System

Modello TH2829LX TH2829AX TH2829AX-24 TH2829AX-48 TH2829NX TH2829CX
Test Pin(PIN) 20 20 24 48 72/96/120/144/168/192 20
Frequenza di prova 20Hz — 200kHz 20Hz — 1MHz
Schermo 800×RGB×480 7 inch TFT LCD display
LCR Function option
Transformer test parameters Turn Ratio, Turns, Phase, l, C, Lk, Q, ACR, DCR, Bilancia, Pin Short, Diode P/N
LCR Test Parameters |Z|,Y|, C, l, X, B, R, G, D, Q, io, DCR, Turn-Ratio, Phase, Lk
Basic Test Accuracy LCRZ 0.05%
DCR,Turn Ratio 0.1%
Signal Source Output Impedance 10OH,30OH,50OH,100OH
Prova velocità (ms/times) 13ms, 90 ms, 370 ms
AC Signal Level 5mVrms — 2Vrms(transformer test, can be customized to 10Vrms), 5mVrms — 10Vrms(LCR function);50μArms — 100mArms
DC Bias Voltage Source —— 0V — ± 10V;0mA — ± 100mA
DC Bias Current Source 0 — ±1A option(option TH2901) / 0 — ±2A option(option TH2902)
DC Constant Current Source 0mA – ±120mA for diode forward characteristic test
Diode Test forward test voltage 0 — 9.9999 V
Reverse test current 0 — 99.999 mA
Comparatore 10 bins, PASS/FAIL indication, file counting function
Magazzinaggio Internal: 100 sets of configuration file;U disk: 500 sets of configuration files, CSV

Transformer Test System Transformer Test System Transformer Test System