GA-Y101 Automatic Micro-Carbon Residue Analyzer
The Automatic Micro-Carbon Residue Analyzer is an instrument used for micro-carbon residue measurement. Its measurement range is for measuring carbon residue in petroleum products.
- Descrizione
- Inchiesta
Descrizione
Descrizione
The Automatic Micro-Carbon Residue Analyzer is an instrument used for micro-carbon residue measurement. The temperature control and program control components are imported from Japan, while the remaining components are domestically produced. It complies with GB/T 17144, ASTM D4530, e ISO 10370 standard. Its measurement range is for measuring carbon residue in petroleum products.
Instrument Performance
An imported programmable temperature controller provides full temperature monitoring, automatic nitrogen pressure monitoring, and automatic flow control. An automatic alarm is activated upon test completion. Fino a 12 tests can be performed simultaneously. Product Description and Overview of the Automatic Micro-Carbon Residue Analyzer: This instrument is designed and manufactured in accordance with the standards GB/T 17144 (Determination of Carbon Residue in Petroleum Products), ASTM D4530, e ISO 10370:1993. It features an attractive appearance and easy operation. Its test results are consistent with those of GB/T 268 (Conradson method).
Parametri tecnici
Control System: PLC Windows
User Interface: Color 12-inch embedded industrial computer, switchable between Chinese and English
WiFi printer connection
Temperature Control Accuracy: ±2°C
Number of Samples: 12
Pressure Sensor: 0-500 KPA. Precisione: ±0.5% FS, other ranges available
Gas Source Pressure: 0-0.5 MPa (customer-provided)
Nitrogen Flow Rate: 150 mL/min – 600 mL/min (per GB/T 17144-1997)
Operating Time: Circa 120 minuti
Working Temperature: ≥25°C
Dimensioni: 380 × 410 × 570 mm (L × W × H)
Instrument Features
Capable of measuring up to 12 samples simultaneously.
Nitrogen shielding gas flow ensures consistent test conditions and excellent repeatability and reproducibility.
The exhaust gas is discharged using a duct, providing greater flexibility in laboratory space requirements compared to Kang’s method.
Axial fan cooling helps keep the instrument temperature down.
Operation requires only pressing the “Start” button, and the instrument automatically performs all tests. No further operation or judgment is required during normal operation. A buzzer indicates the end of the test. The display is intuitive and easy to read.