GA-G139 Portable Ultraviolet Flue Gas Analyzer
Modello:GA-G139
- Descrizione
- Inchiesta
Descrizione
GA-G139 Portable Ultraviolet Flue Gas Analyzer
introduzione al prodotto:
The portable ultraviolet flue gas analyzer is based on ultraviolet differential absorption spectroscopy, non-dispersive infrared technology, and long-life electrochemical sensing technology. It can simultaneously measure the volume concentrations of SO2, NOx, CO, CO2, O2, and HC in flue gas. It can be optionally equipped with an integrated sampling and heating device and a portable pre-treatment device, which does not alter the composition of the measured gas, meeting the detection requirements of analytical instruments. It is a high-performance portable product specifically designed for environmental monitoring, energy-saving monitoring, energy efficiency testing, and environmental science research.
GA-G139 Portable Ultraviolet Flue Gas Analyzer
Caratteristiche del prodotto:
Based on ultraviolet differential absorption spectroscopy technology to measure SO2/NO, using the DOAS algorithm, it is unaffected by moisture and dust, and there is no cross-interference between the measured gases, meeting the requirements for ultra-low emission monitoring.
Using non-dispersive infrared dual-beam gas analysis technology and long-life electrochemical sensing technology to measure CO/CO2/O2, ensuring no cross-interference between the measured gases, high measurement accuracy, and long sensor lifespan.
The analyzer can be optionally equipped with an integrated sampling and heating device and a portable pre-treatment device, meeting the requirements for flue gas sampling and instrument analysis after filtration, dust removal, condensation, and flow control, without altering the composition of the measured gases in the flue gas.
GA-G139 Portable Ultraviolet Flue Gas Analyzer
Application Areas:
Environmental monitoring and enforcement, boiler and kiln efficiency testing, checking burner operating conditions, checking equipment leaks
GA-G139 Portable Ultraviolet Flue Gas Analyzer
Parametri tecnici
| Measured Components | SO2、NO、CO、CO2、O2 |
| Measurement Principle | SO2/NO/CO/CO2:UV-DOAS ; O2:ECD |
| Campo di misura
|
SO2/NO:(0~100/200/500)mg/m3 CO:(0~5000)ppm CO2/O2:(0~25)% |
| Linearity Error | ±2%F.S. |
| Ripetibilità | ≤2% |
| Tempo di risposta | T90<15s |
| Warm-up Time | 30min |
| Stabilità | ≤2%F.S./24h |
| Sample Flow Rate | (0.7~1.2)L/min |
| Dimensioni | 275mm*470mm*175mm |
| Peso | 7.5kg |
| Electrical Parameters | |
| Alimentazione elettrica | 100~240VAC,80W |
| Schermo | LCD display |