Keterangan

BGD 876 Ruang Kondensasi Paparan dalam kabinet

BGD 876 Ruang Kondensasi Paparan dalam kabinet is designed according to ISO 6270-2《Paints and varnishes — Determination of resistance to humidity — Bagian 2: Condensation (in-cabinet exposure with heated water reservoir)》. This standard is different with Part 1“Continuous condensation” , but defines three cyclic program:CH(Condensation atmosphere with constant humidity), AHT(Condensation atmosphere with alternating humidity and air temperature),AT(Condensation atmosphere with alternating air temperature) to simulate different humidity environment.

It can give much better supplements and explanation for corrosion degree and defect types of coating used in different environment. Comparing to Part 1—single-sided exposure, this method add a condensation atmosphere with alternating humidity and air temperature, and mainly used to evaluate paints anti-corrosion ability under different environment.

BGD 876 Ruang Kondensasi Paparan dalam kabinet

Condensation Test Atmospheres

Test Atmosphere Cycle Duration Conditions in working chamber after reaching equilibrium
Type Kode Test PeriodS Total Air Temperature Relative Humdity
Constant-humidity condensation atmosphere CH From warm-up to end of exposure (40±3)℃ Approx.100% with condensation on test specimens
Alternating condensation atmosphere With alternation of humidity and air temperature AHT 8h including warm-up 24h (40±3)℃

 

Approx.100% with condensation on test specimens
16h including cooling-d 18℃ to 28℃ Approaching ambient
With alternation of air temperature AT 8h including warm-up 24h (40±3)℃ Approx.100% with condensation on test specimens
16h including cooling down(chamber closed) 18℃ to 28℃ Approx.100%(approximately saturated)

BGD 876 Ruang Kondensasi Paparan dalam kabinet

◆ Designed with automatic ventilator, can control chamber ventilation automatically.

◆ Operator can set three different working conditions:humidification, cooling with ventilation, cooling without ventilation and its corresponding temperature & running time. Any program including total test time and cycle times can be set freely.

◆ Automatic water supply

◆ Protector for water temperature ceiling

◆ A glass observation window is designed in chamber, operator can observe specimens test status directly.

BGD 876 Ruang Kondensasi Paparan dalam kabinet

Operation Menu

BGD 876 Ruang Kondensasi Paparan dalam kabinet

Parameter Teknis Utama

Test Specimens Capacity:20 pcs(150mm×70mm standard size)

Temperature Range of Working Room:RT~60°(Dry or condensation)

Ukuran keseluruhan:800mm×750mm×1420mm(L×W×H)

Berat:180kg

Kekuatan:220V 50HZ;Maks. power of machine:2.0KW

■ Informasi Pemesanan:Ruang Kondensasi Paparan dalam kabinet

BGD 876 Ruang Kondensasi Paparan dalam kabinet